(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer

Modell nr.
C2

IP Rating
IP65

Certifiering
ISO

Anpassad
Anpassad

Produktion
Analog Sensor

Användande
Hall Sensor

Theory
Hall Sensor

Supply Voltage
+-12, +-15

Power Consumption
<25

Offset Voltage
@IP=0 +-20

Galvanic Isolation
@ 50Hz, AC, 1min 2.5

Isolation Resistance
@ DC 500V 1000

Transportpaket
Export and Air-Worthy Standard Carton

Specifikation
IEC 6044-1

Varumärke
HEYI

Ursprung
Liushi, Yueqing, Zhejiang Province, Kina

HS-kod
8542390000

Produktionskapacitet
100000st/år

Beskrivning

C2 series dismountable hall effect current sensor is an open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.

Electrical data (Ta=25ºC±5ºC,RL=2KΩ,CL=10000PF)
Typ C2-100A C2-200A C2-300A C2-400A C2-500A Unit
Märkström(Ipn) ±100 ±200 ±300 ±400 ±500 A
Measure range(Ip) 0-±200 0-±400 0-±600 0-±800 0-±1000 A
Rated output @Ip=±Ipn ±4±1% V
Supply voltage ±12,±15 V
Power Consumption <25 mA
Offset voltage @Ip=0 ±20 mV
Magnetic offset @Ip=±Ipn-0 ±20 mV
Offset drift @ -40~+85ºC ≤±1 mV/ºC
Output drift @ -40~+85ºC ≤±1 mV/ºC
Linearity @Ip=0-±Ipn ≤1 %FS
Response time @50A/μS, 10%-90% ≤5 μs
Galvanic isolation @ 50HZ,AC,1min 2.5 KV
Isolation resistance @ DC 500V 1000

Ansökningar

·Variable speed drives
·Welding machine
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
·Electrochemical

Mechanical dimension(for reference only)


Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation: 1:+15V 2:-15V 3:V0UT 4:0V

Directions for use

1. When the current will be measured goes through a sensor, the voltage will be measured at the output end.(Note: The false wiring may result in the damage of the sensor)
2. Custom design in the different rated input current and the output voltage are available.

Standards

·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000

General date
Value Unit
Driftstemperatur(TA) -40 till +85 ºC
Förvaringstemperatur(TS) -40 till +125 ºC
Mass(approx) (M) 70 g

Characteristics chart

Pulse current signal response characteristic:
(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer

Effects of impulse noise:

(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer