Ahkc-Ekaa DC 0-500A 4-20mA Analog Split Core Open-Loop Toroidal Hall Effect Current Sensor with Real-Time Value for Solar Telecom Base Station DC Charging Pile

Modell nr.
AHKC-EKAA

Certifiering
CE

Anpassad
Non-Customized

Produktnamn
Split Core Open-Loop Hall Current Sensor

Stämpla
OEM ODM

Current Range
DC 0~500A

Produktion
4-20mA

Accuracy
Class 0.5

Strömförsörjning
12V/24V

Hole Size
20mm

Transportpaket
Fob Shanghai

Varumärke
ACREL

Ursprung
Kina

Produktionskapacitet
1000PCS/Per Month

Beskrivning

Produktbeskrivning

AHKC-EKAA Split Core Open-loop Hall Effect Current Sensor

General

Hall current sensors are mainly used to isolate and convert AC, DC, pulse and other complex signals. After signals are converted according to the Hall Effect Theory, they can be directly acquired by AD, DSP, PLC, secondary instruments and other devices. Hall current sensors are widely applicable for acquisition and feedback control of current signals in the current monitoring, battery application, inverter, solar power management, direct current cabinet, DC motor drive, electroplating, welding, frequency converter, UPS servo control systems. They feature the quick response, wide range of measurement, high precision, strong overload capacity, good linearity and excellent anti-interference performance.

Drag

1.Measure AC, DC, pulse and other complex current
2.Small package size
3.Low power consumption
4. Extended measuring range

Ansökan
1.AC variable speed drives
2. Battery supplied applications
3. Uninterruptible Power Supplies
4.Power supplies for welding application

Technical Parameters

Technical parameters Data
Split/closed open-loop Hall (true RMS)
Produktion Nominal value Spänning: ±5V/±4V Current: 4-20mA
Zero offset voltage (current) Spänning: ±20mV Current:±0.05mA
Offset voltage (current) drift Spänning: ≤±1.0mV/ºC Current:±0.04mA/ºC
Linearity ≤0.2%FS
Power voltage DC±15V DC 24V
Bandwidth 0-20kHz
Response time ≤5us ≤1ms
Dielectric strength Permissible 2500VAC between input/ output and power supply at the power frequency
Accuracy class 1.0
Ambient conditions Temperatur Driftstemperatur:-25ºC-+70ºC;
storage temperature: -40ºC-+85ºC
Humidity ≤95%RH, no dew, no aggressive gas
Höjd över havet ≤3500m

Quotation

Ahkc-Ekaa DC 0-500A 4-20mA Analog Split Core Open-Loop Toroidal Hall Effect Current Sensor with Real-Time Value for Solar Telecom Base Station DC Charging Pile
Ahkc-Ekaa DC 0-500A 4-20mA Analog Split Core Open-Loop Toroidal Hall Effect Current Sensor with Real-Time Value for Solar Telecom Base Station DC Charging Pile

Ahkc-Ekaa DC 0-500A 4-20mA Analog Split Core Open-Loop Toroidal Hall Effect Current Sensor with Real-Time Value for Solar Telecom Base Station DC Charging Pile