(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer

Модель №.
C2

IP-рейтинг
IP65

Сертификация
ИСО

Индивидуальные
Индивидуальные

Output
Analog Sensor

Использование
Hall Sensor

Theory
Hall Sensor

Supply Voltage
+-12, +-15

Power Consumption
<25

Offset Voltage
@IP=0 +-20

Galvanic Isolation
@ 50Hz, AC, 1min 2.5

Isolation Resistance
@ DC 500V 1000

Транспортный пакет
Export and Air-Worthy Standard Carton

Технические характеристики
IEC 6044-1

Товарный знак
HEYI

Источник
Liushi, Yueqing, Zhejiang Province, Китай

Код ТН ВЭД
8542390000

Производственная мощность
100000ПК/год

Описание

C2 series dismountable hall effect current sensor is an open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.

Electrical data (Ta=25ºC±5С,RL=2KΩ,CL=10000PF)
Type C2-100A C2-200A C2-300A C2-400A C2-500A Единица
Rated current(Ipn) ±100 ±200 ±300 ±400 ±500 А
Measure range(Ip) 0-±200 0-±400 0-±600 0-±800 0-±1000 А
Rated output @Ip=±Ipn ±4±1% В
Supply voltage ±12,±15 В
Power Consumption <25 mA
Offset voltage @Ip=0 ±20 mV
Magnetic offset @Ip=±Ipn-0 ±20 mV
Offset drift @ -40~+85ºC ≤±1 mV/ºC
Output drift @ -40~+85ºC ≤±1 mV/ºC
Linearity @Ip=0-±Ipn ≤1 %FS
Response time @50A/μS, 10%-90% ≤5 μs
Galvanic isolation @ 50HZ,AC,1min 2.5 KV
Isolation resistance @ DC 500V 1000

Applications

·Variable speed drives
·Welding machine
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
·Electrochemical

Mechanical dimension(for reference only)


Примечания:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation: 1:+15В 2:-15В 3:V0UT 4:0В

Directions for use

1. When the current will be measured goes through a sensor, the voltage will be measured at the output end.(Note: The false wiring may result in the damage of the sensor)
2. Custom design in the different rated input current and the output voltage are available.

Standards

·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000

General date
Value Единица
Рабочая температура(TA) -40 к +85 С
Температура хранения(TS) -40 к +125 С
Mass(approx) (M) 70 г

Characteristics chart

Pulse current signal response characteristic:
(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer

Effects of impulse noise:

(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer