Solar Inverter Product Description
Off Grid Solar Inverter with Microprocessor control and High efficiency
1: Pure sine wave output (THD< 3%)
2: Build in MPPT solar charge controller 40A or 50A
3: Ups mode and solar inverter mode for your select by switch
Key Features
- AC Charging current 0-35A
- Can choose different types of batteries
- High-low voltage protection
- Against overload, short-circuit Protection
- Over voltage, battery reverse connection(optional)
- Under-voltage and over-temperature protection
- Selectable battery priority or utility priority
- Have UPS function and AC charger function
- AC Grid priority&battery priority working mode are selectable
- AC Grid mode: AC Bypass supplies load when AC is normal, battery invert AC Supplies load when AC is Off
- Battery priority: Battery invert supplies load when battery get full-charged; AC Bypass supplies load When battery low and at the meantime battery get charged from solar controller. It transfers back to
- Battery invert mode when battery gel full charged. It males full use of solar energy and saves electricity.
| Modelo | W1000 So | W1500 So | W2000 So | W3000 So | W4000 So | W5000 So | W6000 So | W8K So | W10K So | W12K So | |
| Input | Rated capacity | 1000C | 1500C | 2000C | 3000C | 4000C | 5000C | 6000C | 8KW | 10KW | 12KW |
| peak power | 3000C | 4500C | 6000C | 9000C | 12000C | 15000C | 18000C | 24KW | 30KW | 36KW | |
| Commercial Power range(VAC) | 110VAC:73~137 120VAC:80~150 | ||||||||||
| 220VAC:145~275 230VAC:152~288 240VAC:158~300 | |||||||||||
| Mains input frequency range | 45-65HZ | ||||||||||
| Battery | DC Voltage | 12 VDC / 24VDC / 48VDC | 48VDC | 48VDC / 96VDC | 96Vdc | ||||||
| DC input voltage range | 12VDC:10.5-15VDC 24VDC:21-30VDC 48VDC:42-60VDC 96VDC:84-120VDC | ||||||||||
| Charger | AC charging | 0A-35A (set on LCD Panel) | |||||||||
| Saída | Capable of starting electric motor | 0.5HP | 1HP | 1.5HP | 2HP | 3HP | |||||
| AVR voltage range (VAC) | 110 / 120 / 220 / 230 / 240±10%(Auto-sensing) | ||||||||||
| Battery over voltage protection | 12VDC:16.7VDC 24VDC:33.4V 48VDC:66.8V 96VDC:134V | ||||||||||
| Battery over voltage alarm | 12VDC:15VDC 24VDC:30V 48VDC:60V 96VDC:120V | ||||||||||
| Battery under voltage protection | 12VDC:10.5VDC 24VDC:21V 48VDC:42V 96VDC:84V | ||||||||||
| Battery low voltage protection | 12VDC:10VDC 24VDC:20V 48VDC:40V 96VDC:80V | ||||||||||
| Transfer time | Typical:5ms(Including detection time) | ||||||||||
| Temperature protection | ≥85C alarm ≥90C machine shut off | ||||||||||
| overload | IPS automatically shut down if overload exceeds 120% of normal value for 10 seconds, IPS automatically resume work if overload comes to rated load. | ||||||||||
| Waveform | Pure sine wave | ||||||||||
| Frequency | Commercial power supply: shared frequency with the commercial inversion state:60/50±0.5 | ||||||||||
| Output frequency range | Tracking automatically | ||||||||||
| (electric supply mode) | |||||||||||
| Solar MPPT Controller | MPPT Controller | 30UMA | 60UMA | 60A or 100A | 100UMA | ||||||
| Max PV Input Power | 360C / 720C / 1440C | 48Vdc: 2880C / 96Vdc: 5760C | 48Vdc:2880C / 4800C | 9600C | |||||||
| /96Vdc:5760C / 9600C | |||||||||||
| Max PV Input Open Circuit Voltage (Voc) | 12/24/48Vdc Max: 190Vdc; 96Vdc Max 230Vdc | ||||||||||
| Mppt Working Voltage Range | 12V: 20-80Vdc, 24: 37-105Vdc, 48V: 72-160Vdc, 96V: 144-230Vdc | ||||||||||
| Temperatura | Temperatura de operação | 0C~70C | |||||||||
| Thermal method | Cooling fan in intelligent control≤42C fan rotates slowly to ≥45C fan rotates fast | ||||||||||
| Appearance | External Size(milímetros) (L*W*H) | 460*230*200milímetros | 650*270*200milímetros | 763*315*248milímetros | |||||||
| Gross Size(milímetros) (L*W*H) | 530*330*255milímetros | 740*350*275milímetros | 840*405*320milímetros | ||||||||
| Net weight(kg) | 17 | 21 | 22 | 29 | 37 | 39 | 43 | 60 | 63 | 65 | |
| Gross weight(kg) | 19 | 22 | 24 | 31 | 40 | 32 | 45 | 64 | 66 | 68 | |
| *Specification is subject to change without prior notice. | |||||||||||