High Accuracy IP68 Waterproof Rogowski Coil Best Electrical Transformer

Modelo NÃO.
Y-FCT

Classificação IP
IP68

Certificação
CE

Personalizado
Personalizado

Current Range(RMS)
0-100ka AC

Sinal de saída(Di/Dt)

Accuracy(Typ.)
Calibrated <0.5% (Central Position, 25C)

Linearity (10% para 100% of Range)
±0.2% of Reading

Bandwidth (-3dB)
1Hz to 100kHz

Internal Resistance
80 ± 10% Ohms/400mm

Conductor Position Sensitivity
±1% of Reading

Output Sensitivity Tolerance
±2%

Thicker Flexible Rogowski Coil
Thicker Flexible Rogowski Coil

Pacote de transporte
Poly Bag for Rogowski Coil, Carton for Poly Bag

Especificação
CE

Marca comercial
Meatrol

Origem
Xangai

Código HS
8504311000

Capacidade de produção
50000PCS/mês

Descrição

Y-FCT
Ø8 Flexible Rogowski coil

  1. High linearity from 1A to 100kA
  2. Wide dynamic range
  3. Very useful with large size or awkward shaped conductors or in places with limited access
  4. No danger from open-circuited secondary
  5. Not damaged by large overloads
  6. Non-intrusive, no power drawn from the main
  1. Measurement uniformity at any position of the conductor inside the coil
  2. Excellent degree of rejection to the external current conductor

Característica
Y-FCT is a flexible current transducer based on Rogowski principle, particularly suitable for measurement in combination with portable devices. Y-FCT coils are available in different sizes and can be supplied according to customers design, therefore they can be used in all those applications, in which traditional transducers are not fitting due to its size and/or weight.
Due to its specific features, flexible Rogowski coil is an extremely confortable solution for current measurement and can be used in a number of cases where traditional current transducer is not the adequate solution.
Y-FCT coil is provided with a shield against the influence of external magnetic fields, therefore it grants a stable measurement from low currents to hundreds of kA. The Rogowski coils must be connected to an electronic integrator for 90° phase shift compensation and frequency equalization. Our DIN-RAIL and panel meters can interface Rogowski coils directly without the need of the external integrators. This is an advantage because there is no external boxes or any power supply with consequent ease of use. The particular features of the Rogowski coils combined with the extremely flexible input programming of our portable meters, allow to carry out measurement by all applications.

What is a Rogowski coil?
Rogowski coils have been used for the detection and measurement of electric currents for decades. They are based on a simple principle: anair-coredcoil is placed around the conductor in a toroidal fashion and the magnetic field produced by the current induces a voltage in the coil. The voltage output is proportional to the rate of change of current. This voltage is integrated, thus producing an output proportional to the current.
By using precision winding techniques, especially developed for the purpose, the coils are manufactured so that their output is not influenced by the position of the conductor within the toroid, and to reject interference from external magnetic fields caused, for example, from nearby conductors.Basically, a Rogowski coil current measuring system consists of a combination of a coil and conditioning electronics.Rogowski coil current transducers are used for the AC measurement.
They can be used in similar circumstances to current transformers but for many applications they have considerable advantages:
Wide dynamic range.
High linearity.
Very useful with large size or awkward shaped conductors or in places with limited access. Thanks to the structure without hard core, the coil can be easily manufactured according to the application or to the available space.
Unlike traditional current transducers, there is no danger from open-circuited secondaries.
They cannot be damaged by large overloads.
They are non-intrusive. They draw no power from the main circuit carrying the current to be measured.
They are also light weighted and in some applications are light enough to be suspended on the conductor being measured.

The transducer does not measure direct currents but, unlike a current transformer, it can carry out accurate measurements of AC component even if there is a large superimposed DC component, since there is no iron core causing saturation. This feature is particularly useful for measuring ripple currents for example in battery charging systems.

Especificação

MODEL Y-FCT-200 Y-FCT-350 Y-FCT-510 Y-FCT-800
Coil length 200milímetros 350milímetros 510milímetros 800milímetros
Window size 50milímetros 100milímetros 150milímetros 240milímetros
Reference
Rated current
600UMA 1000UMA 3000UMA 6000UMA
Coil Resistance 140 (+/-10) Ω 210 (+/-10) Ω 290 (+/-10) Ω 430 (+/-10) Ω
Peso 140g 150g 160g 180g
Razão Calibrated 85mV/k[email protected]Hz 50mV/k[email protected]Hz
Uncalibrated 110mV/k[email protected]Hz
Read Accuracy Calibrated <0.5% (central position, 25C)
Uncalibrated < 5% tolerance (central position, 25C)
Maximum current measurable 100kA
Coil Resistance from 100 para 250 Ω
Coil Section 8milímetros
Lead length 2meter
Temperatura Uncalibrated 200ppm/C
Calibrated 300ppm/C
Position Error ±1% maximum
Output on 0A (zero drift) 0.05mV
Phase error ≤0.5°
Linearity ±0.2% of reading
Bandwidth 1Hz para 100kHz(-3dB)
Operating temperature 30C para 80C
Temperatura de armazenamento 40C para 90C
Other requirements, please contact us to OEM.

Materials

Coil & cable Thermoplastic rubber
flame retardant UL 94 V-0 rated
Couplings PA6 UL 94 V-O rated
Cor(coil) Preto, Yellow, Red, Green, Azul
Shielded 100% coil, 100% output cable

Safety

Certifications CE marked
Complies with
LVD EN 61010-1:2010
EMC EN 61326-1:2013
IP68
Voltage insulation Coil: 3000V
Signal cable:1000V
Safety 1000V CATIII ,600V CATIV

High Accuracy IP68 Waterproof Rogowski Coil Best Electrical Transformer

Dimensions tolerance:
UMA,B,C,F:±5mm, D:±0.2mm,E:±10mm

Dimensões(milímetros) Y-FCT200 Y-FCT350 Y-FCT510 Y-FCT800
A.Windows size UMA 50 105 155 245
B.Windows size B 60 100 150 240
C.Coil O.D. 66 121 171 261
D.Coil section 8
E.Lead Cable Total Length 2000
F:Coil length 200 350 510 800

Safety and warning notes
In order to guarantee safe operation of the transducer and to be able to make proper use of all features and functions,please read these instructions thoroughly!Safe operation can only be guaranteed if the transducer is used for the purpose it has been designed for and within the limits of the technical specifications.

Caution!Risk of danger
Ignoring the warnings can lead to serious injury and/or cause damage!
The electric measuring transducer may only be installed and put into operation by qualified personnel that have received an appropriate training,The corresponding national regulations shall be observed during installation and operation of the transducer and any electrical conductor.The transducer shall be used in electric/electronic equipment the respect to applicable standards and safety requirements and in accordance with all the related systems and components manufacturersoperating instructions.

Caution!Risk of electrical shock
When operating the transducer,certain parts of the module may carry hazardous live voltage(e.g.primary conductor).The user shall ensure to take all measures necessary to protect against electrical shock.The transducer is a build-in device containing conducting parts that shall not be accessible after installation.A protective enclosure or additional insulation barrier may be necessary.Installation and maintenance shall be done with the main power supply disconnected except if there are no hazardous live parts in or in close proximity to the system and if the applicable national regulations are fully observed.

Safe and trouble-free operation of this transducer can only be guaranteed if transport,storage and installation are carried out correctly and operation and maintenance are carried out with care.

WARING!
Do not stress the coil by applying any kind of mechanical force(ie.twisting,puncturing,excessive pressure,tight bending,etc.) which will dramatically degrade the device’s accuracy.