Gtq2z-3p/4p Automatic Transfer Switch ATS with IEC60947-6-1

Modelo NÃO.
GTQ2Z

Marca
Jubang

Certificação
ISO9001, CCC, IEC60947-6-1

Shell Frame Level
63UMA,125UMA,250UMA,400UMA,800UMA

Poles
3p/4p

Atual
6~630A

Controller Installation
One-Piece/Split Type

Pacote de transporte
Wooden Case /Carton

Especificação
IEC60947-6-1 GB14048.11-2002

Marca comercial
JUBANG

Origem
China

Código HS
8536500000

Capacidade de produção
10000PCS/Year

Descrição

Gtq2z-3p/4p Automatic Transfer Switch ATS with IEC60947-6-1GTQ2Z Automatic Transfer Switch

1-OEM Service Offered
2-Payment : LC/TT
3-Entrega : By sea / By train
4-FOB/CIF/CIP

Inscrição: Applicable to rated 400V, 50Hz, rated current 800A and below in the high-rise buildings.
Padrão: IEC60947-6-1 GB14048.11-2002
Parameters: Rated voltage: 400V
Rated current 16-800A

Formed by two high breaking capacity breaker.
Elegant shape, and reliable quality.
Two-stage protection, high breaking capacity
Easy operation and long mechanism life.
With communication interface and fire coupling.
LED indicator board.
Integrated and split type are available.

Modelo GTQ2Z-63 GTQ2Z-63E GTQ2Z-125 GTQ2Z-250 GTQ2Z-400 GTQ2Z-630
IEC60947-6-1
Shell grade current Inm(UMA) 63 125 250 400 630
Rated voltage Ue(V) AC400 50Hz AC400 50Hz AC400 50Hz AC400 50Hz AC400 50Hz
Number of poles 3P/4P 3P 4P 3P 4P 3P 4P 3P 4P
Rated current Ie(UMA) 6, 10, 16, 20, 32, 40, 50, 63 16, 20, 25, 32, 40, 50, 63, 80, 100, 125 140, 160, 180, 200, 225, 250 250, 315, 350, 400 400, 500, 630
Rated insulation voltage Ui(V) 690 800 800 800 800
Rated impulse withstand voltage Uimp(KV) 6 8 8 8 8
Rated short circuit breaking capacity Icn(kA) 5 35 35 35 35
Rated short-circuit turn on capacity Icm(kA) 7.8 73.5 73.5 73.5 73.5
Standby power supply for each other × O O O O
Utilization category AC-33iB AC-33iB AC-33iB AC-33iB AC-33iB
Electrical grade and TSE type Grade CB ATSE Grade CB ATSE Grade CB ATSE Grade CB ATSE Grade CB ATSE
Service life (times) Mechanical life 10000 10000 10000 8000 8000
Electrical life 4000 4000 4000 3000 3000
Operation cycle times (times/hour) 120 120 120 120 120
Actuating circuit breaker GTB6-63 GTM1-125 GTM1-250 GTM1-400 GTM1-630
Wiring mode Fixed/Front-panel wiring Fixed/Front-panel wiring Fixed/Front-panel wiring Fixed/Front-panel wiring Fixed/Front-panel wiring
Structure type A:One-piece B:split type UMA UMA B UMA B UMA B UMA B
Outline dimension (milímetros) Width 215 130 218 218 218 218 320 320 340 340
Comprimento(3/4) 350 185 465 350 512 390 640 527 735 623
Altura 135 115 145 145 160 160 243 243 243 243
×: without this function O :Standard configuration

Gtq2z-3p/4p Automatic Transfer Switch ATS with IEC60947-6-1
Gtq2z-3p/4p Automatic Transfer Switch ATS with IEC60947-6-1
Gtq2z-3p/4p Automatic Transfer Switch ATS with IEC60947-6-1
Gtq2z-3p/4p Automatic Transfer Switch ATS with IEC60947-6-1
Gtq2z-3p/4p Automatic Transfer Switch ATS with IEC60947-6-1
Gtq2z-3p/4p Automatic Transfer Switch ATS with IEC60947-6-1