(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer

Modelo NÃO.
C2

Classificação IP
IP65

Certificação
ISO

Personalizado
Personalizado

Saída
Analog Sensor

Uso
Hall Sensor

Theory
Hall Sensor

Supply Voltage
+-12, +-15

Power Consumption
<25

Offset Voltage
@IP=0 +-20

Galvanic Isolation
@ 50Hz, AC, 1min 2.5

Isolation Resistance
@ DC 500V 1000

Pacote de transporte
Export and Air-Worthy Standard Carton

Especificação
IEC 6044-1

Marca comercial
HEYI

Origem
Liushi, Yueqing, Zhejiang Province, China

Código HS
8542390000

Capacidade de produção
100000PCS/Year

Descrição

C2 series dismountable hall effect current sensor is an open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.

Electrical data (Ta=25ºC±5C,RL=2KΩ,CL=10000PF)
Tipo C2-100A C2-200A C2-300A C2-400A C2-500A Unidade
Rated current(Ipn) ±100 ±200 ±300 ±400 ±500 UMA
Measure range(Ip) 0-±200 0-±400 0-±600 0-±800 0-±1000 UMA
Rated output @Ip=±Ipn ±4±1% V
Supply voltage ±12,±15 V
Power Consumption <25 MA
Offset voltage @Ip=0 ±20 mV
Magnetic offset @Ip=±Ipn-0 ±20 mV
Offset drift @ -40~+85ºC ≤±1 mV/ºC
Output drift @ -40~+85ºC ≤±1 mV/ºC
Linearity @Ip=0-±Ipn ≤1 %FS
Response time @50A/μS, 10%-90% ≤5 μs
Galvanic isolation @ 50HZ,AC,1min 2.5 KV
Isolation resistance @ DC 500V 1000

Applications

·Variable speed drives
·Welding machine
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
·Electrochemical

Mechanical dimension(for reference only)


Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation: 1:+15V 2:-15V 3:V0UT 4:0V

Directions for use

1. When the current will be measured goes through a sensor, the voltage will be measured at the output end.(Note: The false wiring may result in the damage of the sensor)
2. Custom design in the different rated input current and the output voltage are available.

Standards

·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000

General date
Value Unidade
Operating temperature(TA) -40 para +85 C
Temperatura de armazenamento(TS) -40 para +125 C
Mass(approx) (M) 70 g

Characteristics chart

Pulse current signal response characteristic:
(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer

Effects of impulse noise:

(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer