Tubular Tower Manufacturer for Communication and Transmission Tower

モデル番号.
10kV to 220kV

状態
新しい

Surface
Hot Dipped Galvanized

Length of Per Section
Within 14 Meter Once Forming

Welding
Aws D 1.1

Reliable Qualification
ISO9001:2000

輸送パッケージ
Standard Export Packing

仕様
10kV to 220kV

商標
Xinhuiying Steel

Qingdao China

HSコード
73089000

生産能力
50000 Tons Per Month

説明

Tubular Tower manufacturer for Communication and Transmission tower

形: Polygonal
色: Request
Surface treatment: Hot Dip Galvanized
高さ: 2m-50m Thickness: 2.5mm-30mm
証明書: ISO9001:2008
アイテム: Residential Light Poles
Ground Mounted: Anchor Bolt
Welding: AWS D 1.1

This is the description of Galvanized steel poles uses for electrical transmission line

-Original design and manufacture in accordance with domestic or ANSI/TIA-222-G
-Galvanization: ISO 1461/ASTM A123
-材料: ASTM A572, S355, Q345/Q235, 等
-Material Code: GB/T1591-2008, GB/T700-2006
-Reliable qualification (ISO9001:2000)
-Excellent service including supervision and supplementary components
-Custom designs and operational decorative solutions
-Excellent service including supervision and supplementary components
To design in accordance with PLS software, we need following design parameters:
1. The operational wind speed of the region where the Tower will be use?
2. The Antennas loading of the Tower and at what height ?
3. The Total height of the Tower itself.

高さ From 9 meter to 100 meter
Suit for Electric Power Transmission and Distribution
Polygonal or Conical
材料 Normally Q345B/A572, Minimum Yield Strength ≥ 345 N/mm²
Q235B/A36, Minimum Yield Strength ≥ 235 N/mm²
As well as Hot rolled coil from ASTM A572 GR65, GR50, SS400
Power Capacity 10kV to 220kV
Tolerance of the dimension According to client’s requirement.
Surface treatment Hot dip galvanized Following ASTM A 123, or any other standard by client required.
Joint of Poles Slip joint, flanged connected
標準 ISO 9001:2008
Length of per section Within 14 meter once forming
Welding Standard AWS (American Welding Society ) D 1.1
Thickness 1 mmto 36mm
Production Process Raw material test → Cutting →bending →Welding (longitudinal )→Dimension verify →Flange welding →Hole drilling →sample assemble → surface clean→ Galvanization or powder coating ,painting →Recalibration →Packages
Packages Packing with plastic paper or according to client’s request.
製品名 galvanized steel poles towers uses for electrical line
Length of per section Within 14m once forming without slip joint
Minimum ultimate tensile strength 490mpa
Max ultimate tensile strengt 620mpa


Tubular Tower Manufacturer for Communication and Transmission Tower
Tubular Tower Manufacturer for Communication and Transmission Tower