説明

仕様
| モデル | NS-5 | NS-10 | |||||
| 定格電圧 | AC125V | AC250V | DC30V | AC125V | AC250V | DC30V | |
| Resistive load | 5あ(10あ) | 5あ(10あ) | 4あ | 5あ(10あ) | 5あ(10あ) | 4あ | |
| Light load | NC:1.5A NO:0.7あ | NC:1A NO:0.5あ | 2あ | NC:1.5A NO:0.7あ | NC:1A NO:0.5あ | 2あ | |
| Inductive load | 3あ | 2あ | NC:3A NO:3あ | 3あ | 2あ | NC:3A NO:3あ | |
| Motor load | NC:2.5A NO:1.3あ | NC:1.5A NO:0.8あ | 3あ | NC:2.5A NO:1.3あ | NC:1.5A NO:0.8あ | 3あ | |
| Contact appearance | Rivet | ||||||
| Contact material | AgSnO2 | ||||||
| Min applicable load | DC5V 160mA | ||||||
| Operating speed | 0.1mm~1m/s | ||||||
| Permissible operating frequency | 機械式:200 operations/min Electrical:30 operations/min | ||||||
| Contact resistance | 30mΩ max. (Initial value) | ||||||
| Insulation resistance | 100mΩ min.(at DC500V) | ||||||
| Dielectric strength | 1000V, 50/60Hz 1min between terminals of the same polarity | ||||||
| 1500V, 50/60Hz 1min between each terminal and no-current-carrying metal parts | |||||||
| 1500V, 50/60Hz 1min between current-carrying metal parts and ground | |||||||
| 保護グレード / PTI | IEC IP40 / 175 | ||||||
| Protection grade of electric shock | Class | ||||||
| Operating ambient | 温度: -25°C ~ 125°C(with no icing or condensation) 湿度: 60% RH max. |
||||||
| Endurance | 機械式: 1,000,000 operations min. 電気: 50,000 operations min. |
||||||
Contact Form


Wiring Diagram


| Operation chatacteristics | NS-10G | NS-5G | NS-5G-F | |
| Operating force | OF Max. | 0.49N | 0.49N | 0.16N |
| Releasing force | PF Min. | 0.06N | 0.06N | 0.02N |
| Pre-travel | PT Max. | 1.0mm | 1.2mm | 1.2mm |
| Over-travel | OT Min. | 1.0mm | 0.8mm | 0.8mm |
| Movement differential | MD Max. | 19.3mm | ||
| Operating position | OP | 14.5`±0.8mm | ||