Descrizione
Marchio: SUNTREE
Model Number: SQ5
Massimo. Attuale: 3200UN
Massimo. Voltaggio: 400V
Corrente nominale(In): 16-100UN
Rated Voltage: Max 1000V
Motor Votage: 12V/48V/110V
Main power: 0-1000V
Standby Power(Generator Power): AC 0-690V
Catagory: DC-31, PC grade
Operation Voltage: 230V-500V, can be adjusted
Changeover action: When Main power voltage reach 500V or above,
Tipo: I-II, I-O-II. Auto & Manual. 3Palo, 4Poli.
Indicator:With Indicate light for Main power, and standby power.
Supply Ability
Porta: Ningbo/Shanghai
Lead Time :
| Quantity(Pieces) | 1 – 1 | >1 |
| Est. Time(giorni) | 15 | To be negotiated |
SQ5 Description
Main power and standby power or mutual standby power change over system or city power and generator group overload switch-over. At the same time, it can operated under un-frequency on and off circuit act as disconnector.
Widely used at the field of important power supply site, which transport, distribution power supply system and automatization system. For fire protection,hospital,bank,building,eccetera, where doesn’t allow power off.
|
Conventional thermal current lth A
|
SQ5 Series
|
||||
|
Rated current ln(UN)
|
63UN
|
80UN
|
100UN
|
||
|
Rated impulse withstand voltage Ui(UN)
|
500
|
500
|
500
|
||
|
Dielectric strength(V)
|
3000
|
3000
|
5000
|
||
|
Rated Working current le(UN) |
380UN
|
AC-31
|
63
|
80
|
100
|
|
AC-33
|
40
|
63
|
80
|
||
|
AC-35
|
63
|
80
|
100
|
||
|
220UN
|
DC-31
|
63
|
80
|
100
|
|
|
DC-33
|
40
|
63
|
80
|
||
|
DC-35
|
63
|
80
|
100
|
||
|
Motor power P(380V)kW
|
30
|
30
|
32
|
||
|
Rated breaking capbility(A Rms)AC33 380V
|
500
|
640
|
800
|
||
|
Rated making capability(A Rms)AC33 380V
|
630
|
800
|
1000
|
||
|
Rated short-current making capability lcm(kA peak value)
|
10
|
10
|
10
|
||
|
Electric durability
|
COSφ=0.65 AC33
|
2000
|
2000
|
2000
|
|
|
Change-oner time
|
IO-0-II or II-0-IO (s)
|
1
|
1
|
1
|
|
|
IO-0 or II-0 (s)
|
0.5
|
0.5
|
0.5
|
||
|
Power wer consumption of electrical control
|
24V(DC)(w)
|
25
|
25
|
25
|
|
|
Moment of operation(Nm)
|
25
|
25
|
25
|
||
Basic Type:Main-standby power, self-cast, seif reset.
Tipo 1:100A below, city power-city power self-cast, self reset Two way power three phase short phase testing; Above 125A, city power-city power main and standby or mutual power can do selection self-cast two way power three phase checking
Tipo 2: City Power-city power main and standby or mutual power supply can do selection(that is self-casting self reset or self-casting without self reset), two way power three phase and lack phase, overload voltage checking
Tipo 3: city power-oil machine, self casting self reset, two way power supply three phase and
lack phase, overload voltage, oil machine frequency testing.




r R&D Strength
Q:Il tuo generatore ATS sembra perfetto, ma qual è la differenza tra te e altri fornitori?Perché trovo un prezzo più economico dagli altri!
UN: Our generator ATS are high quality customized.for solar system I think compare the quality first and then compare the price is the best way.
Q:Posso ottenere un campione prima dell'ordine perché non sono davvero come è la qualità del tuo generatore?
UN:Ovviamente!We also think sample order is the best way to build the trust.
Q:Come va la consegna?Because I really need them is urgently?
UN:Per l'ordine di esempio 10 ~ 15 giorni non sarà un problema e per l'ordine regolare promettiamo in 15 giorni
Q:Com'è il periodo di garanzia per il tuo generatore ATS?
UN:We offer two year warranty for our customer.