1. Applied Standards & Rules:
Measuring and conversion IEC 688 / 1992 – 04
Dielectrical strength IEC 688 2KVac / 1 min.
Surge and Impulse test ANSI C37.90 / 1989
IEC 255-3 (1989) 4Kv 1.2 x 50 noi

2. Modello:
FPA 1 unit of avg. to rms conversion
FPAX 3 unit of avg. to rms conversion
FPAR Ture rms conversion

3.Order form:

4.Ingresso & Output parameters:
Fpa, Fpax, Fpar, AC Current Transducers
Py : DC24 / 48 / 125 V ± 20% or other range under specified

Note:
External power mode suitably for all output types
Internal power mode, only suitably for 0-1mA / 0-20mA / 0-1V / 0-5V / 0-10V output

5.Specifica:
Accuracy ( 23±3°C ) 0.2% RO ………. FPA, FPAX, FPV, FPVX
0.2% RO ………. FPAR, FPVR
Maximum output load DC current mode : maximum 10V drop
DC voltage mode : maximum 5mA drive
Dielectric strength AC 2KV 1 minute between terminals; AC 2.6KV 1 minute / terminals to case
Surge and impulse test ANSI C37.90 / 1989, IEC 255-3 (1989) 4 Kv 1.2 x 50 noi
Maximum input over Current related input Voltage related input
1UN / 5A 10A
4 x rated / continuous 2 x rated / continuous 1.5 x rated / continuous
10 x rated / 10 seconds 25 x rated / 1 second 2 x rated / 10 seconds
50 x rated / 1 second 50 x rated / 0.5 second
80 x rated / 0.5 second
Input burden Current less 0.2 VA; voltage less 0.1 VA
Tempo di risposta & ripple Ø400 ms for step change 0-99% ripple less 0.5% ro peak to peak
Frequency 45 ~ 400 Hz
Stability Temperature range ( 20 to 30°C ) long term stability / year
Maximum 60 ppm / °C less 0.2% draft / year typically
Storage condition Temperature range -25 to 70°C, RH 20 A 95% non condensed
Operating condition Temperature range -20 to 65°C, RH 0 A 99% non condensed
Magnetic field effect < 0.01% Sotto 100 ampere turns at 1M center
Power dissipation Maximum 3.5 VA for FPA / FPAR / FPV / FPVR; 8 VA for FPAX / FPVX

6.Terminal Connection
Fpa, Fpax, Fpar, AC Current Transducers

Model and Ordering
FPA-An-Fn-Pn-On

Example:

1. FPA-A2-F1-P2-03

Ingresso:5UN
Auxiliary Frequency:50Hz
Power:AC 220V
Produzione:4-20mA

If you have any questions about this,welcome to contact us.
We are all at service.
Fpa, Fpax, Fpar, AC Current Transducers


Technical Specification

Reference Standard
GB/T 13850-1998(IEC688-1992)
Accuracy
Long Term stability ≤±0.2%/year.No accumulation error
Temperature influence ≤ 100ppm/oC
Response Time
<400ms
Output Ripple <0.4%(peak-peak value)
Input burden Current less 0.2VA;voltage less 0.1VA
Frequency Nominal frequency ±10%
Maximum output load Current output Max10V pressure drop
Auxiliary power Ratedvoltage80%-120%,rated current 90%-110%
Auxiliary load effect
<± 0.1%
Allow excessive input Current 3rate continuous 10rate 30 secs voltageMax 2ratecontinuous
Dielectric strength Input /output /power/between the crust 2KV AC 1 minIEC866
Impact test ANSIC37.90a/1973,IEC255-4 (5kV1.2/50us PulsedVoltage)
Calibration amplitude Full scale least±3%,zero least±1%
Magnetic field effect 0.4KA/m magnetic field strength change <0.05%
Operating condition Temperature -10~55oC relative humidity≤95%RHnoncondensing
Storage condition Temperature -40~70oC relative humidity ≤95% RHnoncondensing

Haiyan Jinhan Electronic Technology CO.,LTD
FP Series Electric Quantity Transmitter

FPA FPAR FPAT FPAX
FPV FPVR FPVT FPVX
FPW FPW201 FPW301 FPWT FPWT201
FPK FPK201 FPK301 FPKT FPKT201
FPWK FPWK201 FPWK301 FPWKA FPWKA201 FPWKA301
FPWH FPWH201 FPWH301 FPKH FPKH201 FPKH301
FPWWH FPWWH201 FPWWH301 FPKKH FPKKH201 FPKKH301
FPF FPFT FPPF FPPFT FPH FPS
FPD-1 FPD-2 FPDH-1 FPDH-2 FPT-1 FPT-2

We can provide the product model and specifications:

Product Model No.
AC current transducer JD194-BS4I-N
AC voltage transducer JD194-BS4U-N
AC current transducer JD194-BS4I
DC current transducer JD194-BS5I
AC voltage transducer JD194-BS4U
DC voltage transducer JD194-BS5U
Power transmitter JD194-BS4P
Power transmitter JD194-BS4Q
Power factor transducer JD194-BS4H7
Frequency transmitter JD194-BS4F7
Integrated transmitter JD194-BS4Z6
Integrated transmitter JD194-BS4Z8
Integrated transmitter JD194-BS4Z-S
Temperature transmitter BS6T
Resistance transducer BS6R
Intelligent signal conditioner BS6M
AC current transducer RPA
AC voltage transducer RPV
AC current transducer RPAT
AC voltage transducer RPVT
AC current transducer RPAX
AC voltage transducer RPVX
Power transmitter RPW
Power transmitter RPK
Power transmitter RPWK
Power factor transducer RPPF
Frequency transmitter RPF
Frequency transmitter RPFT
AC current transducer CPA
AC voltage transducer CPV
AC current transducer CPAT
AC voltage transducer CPVT
AC current transducer CPAX
AC voltage transducer CPVX
Power transmitter CPW
Power transmitter CPK
Power transmitter CPWK
Power factor transducer CPPF
Frequency transmitter CPF
Frequency transmitter CPFT
Power transmitter FPW
Power transmitter FPK
Power transmitter FPWT
Power transmitter FPKT
Power transmitter FPWK
DC transducer FPD-1H
DC transducer FPD-2H
DC transducer FPDH-1H
DC transducer FPDH-2H
AC current transducer FPA
AC voltage transducer FPV
AC current transducer FPA2
AC voltage transducer FPV2
AC current transducer FPAR
AC voltage transducer FPVR
AC current transducer FPAT
AC voltage transducer FPVT
AC current transducer FPAX
AC voltage transducer FPVX
AC current transducer FPAX2
AC voltage transducer FPVX2
AC current transducer GPA
AC voltage transducer GPV
AC current transducer GPA2
AC voltage transducer GPV2
AC current transducer EPA
AC voltage transducer EPV
AC current transducer GPAT
AC voltage transducer GPVT
AC current transducer GPAX
AC voltage transducer GPVX
AC current transducer GPAX2
AC voltage transducer GPVX2
AC current transducer GPAS
AC voltage transducer GPVS
Generator negative sequence current meter FPFX-100
Temperature transmitter FT3
Temperature transmitter FT2
Temperature transmitter FT2-C
Temperature transmitter GPT
Temperature transmitter EPT
Shift transmitter FPB

Share This Story, Choose Your Platform!