(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer

Modello numero.
C2

Grado di protezione IP
IP65

Certificazione
ISO

Personalizzato
Personalizzato

Produzione
Analog Sensor

Utilizzo
Hall Sensor

Theory
Hall Sensor

Supply Voltage
+-12, +-15

Power Consumption
<25

Offset Voltage
@IP=0 +-20

Galvanic Isolation
@ 50Hz, AC, 1min 2.5

Isolation Resistance
@ DC 500V 1000

Pacchetto di trasporto
Export and Air-Worthy Standard Carton

Specifica
IEC 6044-1

Marchio
HEYI

Origine
Liushi, Yueqing, Zhejiang Province, Cina

Codice HS
8542390000

Capacità produttiva
100000PZ/Anno

Descrizione

C2 series dismountable hall effect current sensor is an open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.

Electrical data (Ta=25ºC±5ºC,RL=2KΩ,CL=10000PF)
Tipo C2-100A C2-200A C2-300A C2-400A C2-500A Unit
Corrente nominale(Ipn) ±100 ±200 ±300 ±400 ±500 UN
Measure range(Ip) 0-±200 0-±400 0-±600 0-±800 0-±1000 UN
Rated output @Ip=±Ipn ±4±1% V
Tensione di alimentazione ±12,±15 V
Power Consumption <25 mA
Offset voltage @Ip=0 ±20 mV
Magnetic offset @Ip=±Ipn-0 ±20 mV
Offset drift @ -40~+85ºC ≤±1 mV/ºC
Output drift @ -40~+85ºC ≤±1 mV/ºC
Linearity @Ip=0-±Ipn ≤1 %FS
Tempo di risposta @50A/μS, 10%-90% ≤5 μs
Galvanic isolation @ 50HZ,AC,1min 2.5 Kv
Isolation resistance @ DC 500V 1000

Applicazioni

·Variable speed drives
·Welding machine
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
·Electrochemical

Mechanical dimension(for reference only)


Osservazioni:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation: 1:+15V 2:-15V 3:V0UT 4:0V

Directions for use

1. When the current will be measured goes through a sensor, the voltage will be measured at the output end.(Note: The false wiring may result in the damage of the sensor)
2. Custom design in the different rated input current and the output voltage are available.

Standards

·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000

General date
Valore Unit
Temperatura operativa(TA) -40 A +85 ºC
Temperatura di conservazione(TS) -40 A +125 ºC
Mass(ca) (M) 70 G

Characteristics chart

Pulse current signal response characteristic:
(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer

Effects of impulse noise:

(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer