(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer

מספר דגם.
C2

IP Rating
IP65

הסמכה
ISO

Customized
Customized

Output
Analog Sensor

Usage
Hall Sensor

Theory
Hall Sensor

Supply Voltage
+-12, +-15

צריכת חשמל
<25

Offset Voltage
@IP=0 +-20

Galvanic Isolation
@ 50Hz, AC, 1דקה 2.5

Isolation Resistance
@ DC 500V 1000

חבילת הובלה
Export and Air-Worthy Standard Carton

מִפרָט
IEC 6044-1

סִימָן מִסחָרִי
HEYI

מָקוֹר
Liushi, Yueqing, Zhejiang Province, חרסינה

קוד HS
8542390000

קיבולת ייצור
100000PCS/שנה

תיאור

C2 series dismountable hall effect current sensor is an open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.

Electrical data (Ta=25ºC±5ºC,RL=2KΩ,CL=10000PF)
סוּג C2-100A C2-200A C2-300A C2-400A C2-500A יְחִידָה
Rated current(Ipn) ±100 ±200 ±300 ±400 ±500 א
Measure range(Ip) 0-±200 0-±400 0-±600 0-±800 0-±1000 א
Rated output @Ip=±Ipn ±4±1% V
Supply voltage ±12,±15 V
צריכת חשמל <25 mA
Offset voltage @Ip=0 ±20 mV
Magnetic offset @Ip=±Ipn-0 ±20 mV
Offset drift @ -40~+85ºC ≤±1 mV/ºC
Output drift @ -40~+85ºC ≤±1 mV/ºC
Linearity @Ip=0-±Ipn ≤1 %FS
Response time @50A/μS, 10%-90% ≤5 μs
Galvanic isolation @ 50HZ,AC,1דקה 2.5 KV
Isolation resistance @ DC 500V 1000

Applications

·Variable speed drives
·Welding machine
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
·Electrochemical

Mechanical dimension(for reference only)


Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation: 1:+15V 2:-15V 3:V0UT 4:0V

Directions for use

1. When the current will be measured goes through a sensor, the voltage will be measured at the output end.(Note: The false wiring may result in the damage of the sensor)
2. Custom design in the different rated input current and the output voltage are available.

Standards

·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000

General date
עֵרֶך יְחִידָה
Operating temperature(TA) -40 אֶל +85 ºC
Storage temperature(TS) -40 אֶל +125 ºC
Mass(approx) (M) 70 ז

Characteristics chart

Pulse current signal response characteristic:
(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer

Effects of impulse noise:

(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer