Flexible Rogowski Coil Ratio 50mv/Ka Air Cored Current Sensor Current Transducer

Modèle NON.
MRC-16

Indice IP
IP68

Certificat
CE

Personnalisé
Personnalisé

Forfait transport
Poly Bag and Export Carton

spécification
Window size 16mm/24mm/36mm, Weight Approx 100g

Marque déposée
MEATROL

Origine
Chine

Code SH
8504311000

Capacité de production
50000Pièces/an

La description



Flexible Rogowski Coil Ratio 50mv/Ka Air Cored Current Sensor Current Transducer
Flexible Rogowski Coil Ratio 50mv/Ka Air Cored Current Sensor Current Transducer
Technical consultant
Susan

MRC
Ø6 Flexible Rogowski coil fixed by cable ties

  1. High linearity from 1A to 1000A
  2. Wide dynamic range
  3. Very useful with large size or awkward shaped conductors or in places with limited access
  4. No danger from open-circuited secondary
  5. Not damaged by large overloads
  6. Non-intrusive, no power drawn from the main
  1. Measurement uniformity at any position of the conductor inside the coil
  2. Excellent degree of rejection to the external current conductor

Fonctionnalité
MRC is a MINI flexible current transducer based on Rogowski principle, particularly suitable for measurement in combination with portable devices. MRC coils are available in different sizes and can be supplied according to customer’s design, therefore they can be used in all those applications, in which traditional transducers are not fitting due to its size and/or weight.
Due to its specific features, flexible Rogowski coil is an extremely confortable solution for current measurement and can be used in a number of cases where traditional current transducer is not the adequate solution.
MRC coil is provided with a shield against the influence of external magnetic fields, therefore it grants a stable measurement from low currents to hundreds of kA. The Rogowski coils must be connected to an electronic integrator for 90° phase shift compensation and frequency equalization. Our DIN-RAIL and panel meters can interface Rogowski coils directly without the need of the external integrators. This is an advantage because there is no external boxes or any power supply with consequent ease of use. The particular features of the Rogowski coils combined with the extremely flexible input programming of our portable meters, allow to carry out measurement by all applications.

Advantage
Calibrated to 0.5%
6mm section make more stable
Easy to fixed on bus-bar or cable by cable ties
Very competitive price
Related Products
S1 D1 S9 SW A01 A05 ME631 ME432
Applications

  1. Measuring devices, lab instrumentation
  2. Power monitoring & control systems
  3. DC ripple measurement
  4. Harmonics and transients monitoring
  5. Power meter,Power analyzer sensor

What is a Rogowski coil?

Rogowski coils have been used for the detection and measurement of electric currents for decades. They are based on a simple principle: anair-coredcoil is placed around the conductor in a toroidal fashion and the magnetic field produced by the current induces a voltage in the coil. The voltage output is proportional to the rate of change of current. This voltage is integrated, thus producing an output proportional to the current.
By using precision winding techniques, especially developed for the purpose, the coils are manufactured so that their output is not influenced by the position of the conductor within the toroid, and to reject interference from external magnetic fields caused, Par exemple, from nearby conductors.Basically, a Rogowski coil current measuring system consists of a combination of a coil and conditioning electronics.Rogowski coil current transducers are used for the AC measurement.
They can be used in similar circumstances to current transformers but for many applications they have considerable advantages:
• Wide dynamic range
• High linearity.
• Very useful with large size or awkward shaped conductors or in places with limited access. Thanks to the structure without hard core, the coil can be easily manufactured according to the application or to the available space.
• Unlike traditional current transducers, there is no danger from open-circuited secondaries.
• They cannot be damaged by large overloads.
• They are non-intrusive. They draw no power from the main circuit carrying the current to be measured.
• They are also light weighted and in some applications are light enough to be suspended on the conductor being measured.
The transducer does not measure direct currents but, unlike a current transformer, it can carry out accurate measurements of AC component even if there is a large superimposed DC component, since there is no iron core causing saturation. This feature is particularly useful for measuring ripple currents for example in battery charging systems.

spécification

MODÈLE MRC-16 MRC-24 MRC-36
Coil length 80millimètre 97millimètre 130millimètre
Window size 16millimètre 24millimètre 36millimètre
Reference
Courant nominal
100UN 300UN 600UN
Coil Resistance 55 (+/-10) Ω 65 (+/-10) Ω 80 (+/-10) Ω
Masse Approx 100g Approx 102g Approx 105g
Maximum current measurable 100kA
Coil Section 6millimètre
Lead length 2meter
Sortir (di/dt) Uncalibrated 60mV/[Protégé par e-mail] 72mV/[Protégé par e-mail]
Calibrated 50mV/[Protégé par e-mail] 60mV/[Protégé par e-mail]
Read Accuracy Calibrated <0.5% (central position, 25C)
Uncalibrated < 5% tolerance (central position, 25C)
Température Uncalibrated 200ppm/C
Calibrated 300ppm/C
Position Error ±1% maximum
Output on 0A
(zero drift)
≤0.05mV
Phase error 0.5°
Linearity ±0.2% of reading
Bande passante 1Hz pour 100kHz(-3dB)
Operating temperature -30C pour 80C
Température de stockage -40C pour 90C
Other requirements, please contact us to OEM.

Flexible Rogowski Coil Ratio 50mv/Ka Air Cored Current Sensor Current Transducer
Position sensitivity

Conductor Position Typical Error(%)
Adjacent to the clip together mechanism <0.5%
Adjacent to the opposite clip <1%

Matériaux

Coil & cable Thermoplastic rubber
flame retardant UL 94 V-0 rated
Couplings PA6 UL 94 V-O rated
Couleur(coil) Orange
Shielded 100% coil, 100% output cable

Safety

Certifications CE marked
Complies with
LVD EN 61010-1:2010
EMC EN 61326-1:2013
IP68
Voltage insulation Coil: 1000V
Signal cable:1000V
Safety 1000V CATIII ,600V CATIV
Flexible Rogowski Coil Ratio 50mv/Ka Air Cored Current Sensor Current Transducer
Flexible Rogowski Coil Ratio 50mv/Ka Air Cored Current Sensor Current Transducer

Flexible Rogowski Coil Ratio 50mv/Ka Air Cored Current Sensor Current Transducer

Dimensions tolerance:
UN,B,C,F:±1millimètre, D:±0.2millimètre,E:±10millimètre

Dimensions(millimètre) MRC-16 MRC-24 MRC-36
A.Windows size A 22 27.5 36
B.Windows size B 16 24 37
C.Coil O.D. 34 39.5 48
D.Coil section 6
E.Lead Cable Total Length 2000
F:Coil length 80 97 130

Safety and warning notes
In order to guarantee safe operation of the transducer and to be able to make proper use of all features and functions,please read these instructions thoroughly!Safe operation can only be guaranteed if the transducer is used for the purpose it has been designed for and within the limits of the technical specifications.Ensure you get up-to-date technical information that can be found in the latest associated datasheet, please click below link.

Caution!Risk of danger
Ignoring the warnings can lead to serious injury and/or cause damage!
The electric measuring transducer may only be installed and put into operation by qualified personnel that have received an appropriate training,The corresponding national regulations shall be observed during installation and operation of the transducer and any electrical conductor.The transducer shall be used in electric/electronic equipment the respect to applicable standards and safety requirements and in accordance with all the related systems and components manufacturersoperating instructions.

Caution!Risk of electrical shock
When operating the transducer,certain parts of the module may carry hazardous live voltage(e.g.primary conductor).The user shall ensure to take all measures necessary to protect against electrical shock.The transducer is a build-in device containing conducting parts that shall not be accessible after installation.A protective enclosure or additional insulation barrier may be necessary.Installation and maintenance shall be done with the main power supply disconnected except if there are no hazardous live parts in or in close proximity to the system and if the applicable national regulations are fully observed.

Safe and trouble-free operation of this transducer can only be guaranteed if transport,storage and installation are carried out correctly and operation and maintenance are carried out with care.

WARING!
Do not stress the coil by applying any kind of mechanical force(ie.twisting,puncturing,excessive pressure,tight bending,etc.) which will dramatically degrade the device’s accuracy.

Order code

Coil:

Coil Model Coil diameter (millimètre) Output ratio and tolerance Signal cable length
Code:Y-FCT Code:200(Typical rated 500A)
Code:350(Typical rated 1500A)
Code:510(Typical rated 3kA)
Code:800(Typical rated 10kA)
Y-FCT code is length.
Code:110
110mV/[Protégé par e-mail]±5%
Code:100
100mV/[Protégé par e-mail]±0.5%
Code:85
85mV/[Protégé par e-mail]±0.5%
Code:50
50mV/[Protégé par e-mail]±0.5%
Code:-2m
Code:-5m
Code:-10m
Code:-20m
Code:NRC Code:100(Typical rated 1kA)
Code:150(Typical rated 3kA)
Code:200(Typical rated 6kA)
Code:MRC Code:16(Typical rated 100A)
Code:24(Typical rated 300A)
Code:36(Typical rated 600A)
Code:60
60mV/[Protégé par e-mail]±5%
Code:50
50mV/[Protégé par e-mail]±0.5%
Code:SRC Code:50
Code:100
Code:150
Code:360
360mV/[Protégé par e-mail]±5%
Code:333
333mV/[Protégé par e-mail]±0.5%
Code:100
100mV/[Protégé par e-mail]±0.5%
Code:85
85mV/[Protégé par e-mail]±0.5%
Code:50
50mV/[Protégé par e-mail]±0.5%
Other requirement could be OEM

Final Code=Coil model+Diameter(Y-FCT is coil length)+Output ratio+Signal cable length
Par exemple:
NRC-150-100-2m is NRC connector,diameter 150mm,output 100mV/[Protégé par e-mail] 0.5% tolerance,signal cable length is 2meter.

Integrator:

Integrator Output form Output value Courant nominal Source de courant
Code:D1
(DIN-RAIL integrator)
Code: .1(AC voltage output)
Code: .2(DC voltage output)
Code: -333(333mV)
Code: -1(1V)
Code: -5(5V)
Code: -600UN
Code: -1kA
Code: -3kA
Code: -6kA
Code: -12(12À DC)
Code: -24(24À DC)
Code: .3(4-20mA output) N / A
Code:S9
(mini integrator)
Code: .1(AC voltage output)
Code: .2(DC voltage output)
Code: -333(333mV)
Code: -1(1V)
Code: -3(3V)
Code: -12(6-12À DC)
Code: -24(24À DC)
Code:S1
(high accuracy integrator)
Code: .1(AC voltage output)
Code: .2(DC voltage output)
Code: -333(333mV)
Code: -5(5V)
Code: -10(10V)
Code: -12(4-12À DC)
Code: -24(24À DC)
Code: .3(4-20mA output) N / A
Code:ATP-01
(1A output three phase integrator)
N / A(0-1UN) N / A Code: -12(12À DC)
Code: -24(24À DC)
Code:A01
(1A output integrator)
N / A(0-1UN) N / A N / A(85-265V AC DC)
Code:A05
(5A output integrator)
N / A(0-5UN) N / A N / A(85-265V AC DC)
Code:HF
(high frequency integrator)
N / A(0-10VAC peak) N / A Code: -1kA(1kA/1V)
Code: -10kA(10kA/1V)
N / A(4-12À DC)
Other requirement could be OEM


Final Code=Integrator+Output form+Output value+Rated current+Power supply
Par exemple:
D1.1-1-500A-12 is D1 integrator,AC voltage output,500A rated,output 1V,power supply 12V DC
A01-1kA is A01 integrator,rated 1kA,output 1A,power supply 85-265V AC DC

Flexible Rogowski Coil Ratio 50mv/Ka Air Cored Current Sensor Current TransducerFlexible Rogowski Coil Ratio 50mv/Ka Air Cored Current Sensor Current TransducerFlexible Rogowski Coil Ratio 50mv/Ka Air Cored Current Sensor Current TransducerFlexible Rogowski Coil Ratio 50mv/Ka Air Cored Current Sensor Current TransducerFlexible Rogowski Coil Ratio 50mv/Ka Air Cored Current Sensor Current Transducer