(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer

Modèle NON.
C2

Indice IP
IP65

Certificat
OIN

Personnalisé
Personnalisé

Sortir
Analog Sensor

Usage
Hall Sensor

Theory
Hall Sensor

Supply Voltage
+-12, +-15

Power Consumption
<25

Offset Voltage
@IP=0 +-20

Galvanic Isolation
@ 50Hz, CA, 1min 2.5

Isolation Resistance
@ DC 500V 1000

Forfait transport
Export and Air-Worthy Standard Carton

spécification
IEC 6044-1

Marque déposée
HEYI

Origine
Liushi, Yueqing, Zhejiang Province, Chine

Code SH
8542390000

Capacité de production
100000Pièces/an

La description

C2 series dismountable hall effect current sensor is an open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.

Electrical data (Ta=25ºC±5C,RL=2KΩ,CL=10000PF)
Taper C2-100A C2-200A C2-300A C2-400A C2-500A Unit
Courant nominal(Ipn) ±100 ±200 ±300 ±400 ±500 UN
Measure range(Ip) 0-±200 0-±400 0-±600 0-±800 0-±1000 UN
Rated output @Ip=±Ipn ±4±1% V
Supply voltage ±12,±15 V
Power Consumption <25 mame
Offset voltage @Ip=0 ±20 mV
Magnetic offset @Ip=±Ipn-0 ±20 mV
Offset drift @ -40~+85ºC ≤±1 mV/ºC
Output drift @ -40~+85ºC ≤±1 mV/ºC
Linearity @Ip=0-±Ipn ≤1 %FS
Response time @50A/μS, 10%-90% ≤5 μs
Galvanic isolation @ 50HZ,CA,1min 2.5 KV
Isolation resistance @ DC 500V 1000

Applications

·Variable speed drives
·Welding machine
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
·Electrochemical

Mechanical dimension(for reference only)


Remarques:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation: 1:+15V 2:-15V 3:V0UT 4:0V

Directions for use

1. When the current will be measured goes through a sensor, the voltage will be measured at the output end.(Note: The false wiring may result in the damage of the sensor)
2. Custom design in the different rated input current and the output voltage are available.

Standards

·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000

General date
Value Unit
Operating temperature(TA) -40 pour +85 C
Température de stockage(TS) -40 pour +125 C
Mass(approx) (M) 70 g

Characteristics chart

Pulse current signal response characteristic:
(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer

Effects of impulse noise: