Ahkc-Ekaa DC 0-500A 4-20mA Analog Split Core Open-Loop Toroidal Hall Effect Current Sensor with Real-Time Value for Solar Telecom Base Station DC Charging Pile

Modèle NON.
AHKC-EKAA

Certificat
CE

Personnalisé
Non-Customized

Nom du produit
Split Core Open-Loop Hall Current Sensor

Marque
OEM ODM

Current Range
DC 0~500A

Sortir
4-20mame

Accuracy
Class 0.5

Source de courant
12V/24V

Hole Size
20millimètre

Forfait transport
Fob Shanghai

Marque déposée
ACREL

Origine
Chine

Capacité de production
1000PCS/Per Month

La description

Description du produit

AHKC-EKAA Split Core Open-loop Hall Effect Current Sensor

Général

Hall current sensors are mainly used to isolate and convert AC, CC, pulse and other complex signals. After signals are converted according to the Hall Effect Theory, they can be directly acquired by AD, DSP, PLC, secondary instruments and other devices. Hall current sensors are widely applicable for acquisition and feedback control of current signals in the current monitoring, battery application, inverter, solar power management, direct current cabinet, DC motor drive, electroplating, welding, frequency converter, UPS servo control systems. They feature the quick response, wide range of measurement, high precision, strong overload capacity, good linearity and excellent anti-interference performance.

Caractéristiques

1.Measure CA, CC, pulse and other complex current
2.Small package size
3.Low power consumption
4. Extended measuring range

Application
1.AC variable speed drives
2. Battery supplied applications
3. Uninterruptible Power Supplies
4.Power supplies for welding application

Paramètres techniques

Technical parameters Data
Split/closed open-loop Hall (true RMS)
Sortir Nominal value Tension: ±5V/±4V Actuel: 4-20mame
Zero offset voltage (current) Tension: ±20mV Actuel:±0.05mA
Offset voltage (current) drift Tension: ≤±1.0mV/ºC Actuel:±0.04mA/ºC
Linearity ≤0.2%FS
Power voltage DC±15V DC 24V
Bande passante 0-20kHz
Response time ≤5us ≤1ms
Dielectric strength Permissible 2500VAC between input/ output and power supply at the power frequency
Accuracy class 1.0
Ambient conditions Température Operating temperature:-25ºC-+70ºC;
storage temperature: -40ºC-+85ºC
Humidité ≤95%RH, no dew, no aggressive gas
Altitude ≤3500m