Industrial Conductivity Meter High Accuracy

N º de Modelo.
DDG-3080

Stability of The Electronic Unit
±0.2%Fs±1 Unit/24h

Output Current Error
: ≤±l%Fs

Error of Electronic Unit Caused by Ambie
≤±0.5%Fs

Temperatura ambiente
0~ 60ºC

Paquete de transporte
Caja de cartón

Especificación
146 X 146 X 150 milímetro

Marca comercial
Boqu

Origen
China(Continente)

Código hs
9027809900

Capacidad de producción
300 Sets/semana

Descripción

DDG-3080 Industrial Conductivity Meter

DDG-3080 Industrial Conductivity Meter is our company’s latest top-class instrument equipped with a microprocessor and
complete
Inglés menu. It has display and menu operation pattern; it is characterized by its intelligent operation, multi-function
and high measuring performance and its strong environmental adaptability. It can be widely used for continuous monitoring of
the conductivities of solutions used in the following fields: thermal power plant, fertilizante químico, chemical industry, metalurgia,
protección ambiental, pharmacy manufacturing, biochemistry, foodstuff and running water.

Características

It has a complete Inglés display and friendly interface. Various parameters can be displayed at the same
tiempo: conductivity, output current, temperature, time and status. Bitmap type liquid crystal display module
with high resolution is adopted. All the data, status and operation prompts are displayed in English. There
is no symbol or code that is defined by the manufacturer.

Índices técnicos

1.Conductivity measuring range: 0.01~20μS/cm (Electrodo: K = 0.01)
0.1~200μS/cm (Electrodo: K = 0.1)
1.0~2000μS/cm (Electrodo: K = 1.0)
10~20000μS/cm (Electrodo: K = 10.0)
30~600.0mS/cm (Electrodo: K=30.0)
2. Intrinsic error of the electronic unit: conductivity: ±0.5%FS, temperature: ±0.3ºC
3. Range of automatic temperature compensation: 0~199.9ºC, with 25ºC as the reference temperature
4. Water sample tested: 0~199.9ºC, 0.6MPa
5. Intrinsic error of the instrument: conductivity: ±1.0%FS, temperature: ±0.5ºC
6. Automatic temperature compensation error of the electronic unit: ±0.5%FS
7. Repeatability error of the electronic unit: ±0.2%FS±1 Unit
8. Stability of the electronic unit: ±0.2%FS±1 unit/24h
9. Isolated current output: 0~10mA ( load<1.5kOh)
4~ 20 mA (load<750Oh) (double-current output for option)
10. Output current error: ≤±l%FS
11. Error of electronic unit caused by ambient temperature: ≤±0.5%FS
12. Error of the electronic unit caused by the supply voltage: ≤±0.3%FS
13. Alarm relay: CA 220 V, 3A
14. Communication interface: RS485 or 232 (Opcional)
15. Fuente de alimentación: AC 220V±22V, 50Hz±1Hz, 24VCC (Opcional)
16. Grado de protección: IP54 , aluminium shell suitable for outdoor use
17. Clock accuracy: ±1 minute/month
18. Data storage capacity: l month (1 point/5 minutes)
19. Saving time of data under a continuous power-failure condition: 10 años
20. Dimensión general: 146 (longitud) X 146 (width) X 150 (depth) milímetro; dimensión del agujero: 138 x 138mm
21. Working conditions: temperatura ambiente: 0~ 60ºC; relative humidity <85%
22. Peso: 1.5kg
23. The conductivity electrodes with the following five constants are usable: K = 0.01, 0.1, 1.0, 10.0, y 30.0.

Industrial Conductivity Meter High AccuracyIndustrial Conductivity Meter High AccuracyIndustrial Conductivity Meter High AccuracyIndustrial Conductivity Meter High AccuracyIndustrial Conductivity Meter High AccuracyIndustrial Conductivity Meter High AccuracyIndustrial Conductivity Meter High Accuracy