Descripción
This product is suitable for testing of dynamic performance of various types of DC brushless motors with/without load, widely used in household brushless motors, electric vehicle motors, fan motors, drone motors, brushless power tools and other industries.
Broadband: signal detection of 0.5Hz~100KHz ultra-wideband.
High accuracy: measurement accuracy of voltage/current up to 0.2%.
Efficient: One-time wiring to complete all testing items such as static, no load, Hall signal, etc, high efficiency.
One-stop: self-developed AC/DC power supply, convenient and unified before/after sale.
Module: Module test unit to avoid interference, and customize single/multi-station, serial/parallel test system as required.
Multi ports: USB, RS232, LAN and other ports, PLC simulation, TCP/IP network protocol, etc, to facilitate data interaction and instrument control.
High accuracy: measurement accuracy of voltage/current up to 0.2%.
Efficient: One-time wiring to complete all testing items such as static, no load, Hall signal, etc, high efficiency.
One-stop: self-developed AC/DC power supply, convenient and unified before/after sale.
Module: Module test unit to avoid interference, and customize single/multi-station, serial/parallel test system as required.
Multi ports: USB, RS232, LAN and other ports, PLC simulation, TCP/IP network protocol, etc, to facilitate data interaction and instrument control.
Tested items
Stator: withstand voltage, insulation, resistencia, resistance balance, interturn, inductance, rotation
Whole machine: withstand voltage, insulation, resistencia, back electromotive force, no load, speed, Hall, rotation

| Application industries | Household brushless motors, electric vehicle motors, fan motors, drone motors, brushless power tools, etc.. | |||
| Model of product | AN8362S(F) | AN8362M(F) | Custom parameters | |
| Withstand voltage test | Output voltage | Rango: 300 ~ 3000 VACACIONES, step: 10V | 5000 VACACIONES | |
| Allowable error: ± (2.5% x setting +10V) | ||||
| Break down current | Rango: 0.10~20.00 mA | 100 mamá | ||
| Allowable error: ± (2.5% x reading +5 words) | ||||
| Duration | Rango: 1.0~99.9s, allowable error: ± (1% x setting +0.1s) | |||
| Insulation test | Output voltage | Rango: 200 ~ 1000 VCC, step: 5V | ||
| Allowable error: ±(3% x setting +5V) | ||||
| Ripple coefficient | <5% | |||
| Resistance measurement | Rango: 1.0~500MΩ | |||
| Allowable error: ≤200MΩ, ±(3% x reading +5 words) | ||||
| >200MΩ, ±(5% x reading +8 words) | ||||
| Duration | Rango: 1.0~99.9s, allowable error: ± (1% x setting +0.1s) | |||
| Resistance test | Test and measurement | Rango: 0.1~20k Ω, unit: Oh | 1mΩ~400KΩ 1m~400KΩ | |
| Allowable error: ±(0.3% x reading +3 words) | ||||
| Temperature measurement | (0.0~60.0)ºC, allowable error: ±0.5ºC | |||
| Resistance balance | Calculation formula | |Resistance -Resistance average|/Resistance average*100% | ||
| Display range | 0.0%~99.9% | |||
| Interturn test | Pulse voltage | Rango: 300~3000 V, step: 100V | 5000 V | |
| Allowable error: ±(3% x setting +10V) | ||||
| Wavefront time | ≤0.5µs | |||
| Acquisition frequency | 5kHz~40MHz | |||
| Wave parameters | Area, difference area, (1~10) consecutive impacts; range: 0~99% | |||
| Inductance test | Test range | 0.0001μH-99.99kH | ||
| Allowable error | 0.5% | |||
| Test frequency | 100Hz,120Hz,1kilociclos,10kilociclos | |||
| Test level | 0.1,0.3,1.0(V) | |||
| Back electromotive force | Rango de voltaje | (1.0- 300.0 )V; | ||
| Allowable error | ±(0.5% x reading +4 words) | |||
| Range of speed | 100-3000rpm | |||
| No-load test | Rango de voltaje | (50.0- 300.0 )V; | Level-0.02 | |
| Allowable error | ± (0.3% x reading + 0.2% x range) | |||
| Current | (0.05- 20.00 )A; | |||
| Allowable error | ± (0.3% x reading + 0.2% x range) | |||
| Range of power | (1.0-6.0k)W; (1.0-6.0k) W; | |||
| Allowable error | ±(0.8% x reading +0.2% x range) | |||
| Load test | Load range | (0.20-0.75)Nm 0.20-0.75 Nm | ||
| Hall test | Rango de voltaje | (0.5- 10.0 )V | ||
| Allowable error | ±(0.5%×reading value+2) | |||
| Frequency | (10- 1000 )Hz | |||
| Allowable error | ±(0.1%×reading value+1) | |||
| Duty cycle | 20-80%; allowable error ±1% | |||
| Rotation test | Decision parameter | Forward rotation, reverse rotation, no rotation | ||
Optional information