Rmu MID-Set Type Metal-Clad and Metal-Enclosed Switchgear

Αριθμός Μοντέλου.
RMU

Over Voltage Protection
Ναί

Over Current Protection
Ναί

Over Load Protection
Can Be Option

High Temperature Protection
Can Be Option

Under Voltage Protection
Can Be Option

Display
LED, LCD, Analog Meter

Package
Export Carton

Πιστοποιήσεις
CE / ISO9001

Πακέτο μεταφοράς
Normal Export Carton

Προσδιορισμός
CE

Εμπορικό σήμα
HONLE

Προέλευση
Zhejiang, Κίνα

Κωδικός HS
8504401990

Παραγωγική ικανότητα
10000 PCS

Περιγραφή

RMU MID-Set Type Metal-Clad and Metal-Enclosed Switchgear

Rmu MID-Set Type Metal-Clad and Metal-Enclosed SwitchgearRmu MID-Set Type Metal-Clad and Metal-Enclosed SwitchgearRmu MID-Set Type Metal-Clad and Metal-Enclosed Switchgear

Product overview

KYN28A-12(GZS1-12Z) mid-set type metal-clad and metal-enclosed switchgear (hereinafter referred to as switchgear) is a
new type product designed and developed by our company with domestic and international advanced technologies, it is an
ideal upgrading product for replacing the old metal-enclosed switchgear such as KYN1-10, JYN2-10, GBC-10 and so on. Its
advantages as follows:

The cabinet shell is made of al-zinc-coated steel sheet, through CNC processing and multiple bending technique, then assembled with bolts. It is featured with high mechanical strength, neat and elegant appearance, powder coating treated
door, good shock and corrosion resistance. Ingress protection level of the shell reaches IP4X.

Main switch of switchgear can be configured with VD4 vacuum circuit breaker and C3 series fixed type load switch from ABB corporation, also can be configured with many homemade vacuum circuit breakers (such as VS1, VH1, VK, ZN28) instead of overseas similar products.

No matter which circuit breaker selected, make sure that the air insulation distance of its bare conductor is larger than
125mm, and compound insulation is larger than 60mm. The breakers are featured with long service life, high parameters,
less maintenance, small size, και τα λοιπά.

This switchgear is applicable for three-phase power grid of AC 50Hz and class 3.6~12kV, used for electric energy receiving
and distribution, it controls, protects and monitors the circuits, can be used in single bus and single-bus segment system or
dual-bus systems. This switchgear complies with IEC298 Alternating-current metal-enclosed switchgear and controlgear for
rated voltage above 1kV and up to and including 52kV , IEC694 Common specifications for high-voltage switchgear and controlgear, GB3906 Alternating-current metal-enclosed switchgear for rated voltage of 3~36kV, DL404 Indoor AC high voltage switchgear panel, DIN.VDE0670 Alternating-current switchgear for rated voltage above 1kV, και τα λοιπά. It enjoys perfect and reliable anti-misoperation function.

Technical parameters

Technical parameters of switchgear

Είδος Unit Δεδομένα
Ονομαστική τάση
Ονομαστική συχνότητα
Rated current of circuit breaker
Rated current of switchgear
Rated peak withstand current (4s)
Rated peak withstand current (peak)
Rated short-circuit breaking current
Rated short-circuit making current (peak)
KV
Hz
ΕΝΑ
ΕΝΑ
KA
KA

KA

KA

3.6,7.2,12
50
630,1250,1600,2000,2500,3150,4000
630,1250,1600,2000,2500,3150,4000
16,20,25,31.5,40,50,63
40,50,63,80,100,125,160
16,20,25,31.5,40,50,63
40,50,63,80,100,125,160
Rated insulation level 1min power frequency withstand voltage
Lightning impulse withstand voltage
KV
KV
24
40
32
60
42
75
Κατηγορία προστασίας The shell is IP4X, and it is IP2X when the compartment door and circuit breaker chamber door are opened

Technical parameters of VD4 and VS1-12 vacuum circuit breaker

Είδος Unit Δεδομένα
Ονομαστική τάση
Ονομαστική συχνότητα
Rated current of circuit breaker
Rated peak withstand current (4s)
Rated peak withstand current (peak)
Rated short-circuit breaking current
Rated short-circuit making current (peak)
KV
Hz
ΕΝΑ
ΕΝΑ
KA
KA
KA
KA
3.6,7.2,12
50
630,1250,1600,2000,2500,3150,4000
16,20,25,31.5,40,50,63
40,50,63,80,100,125,160
16,20,25,31.5,40,50,63
40,50,63,80,100,125,160
Rated insulation level 1min power frequency withstand KV
KV
42
75
Rated operating sequence
Rated short-circuit current breaking times
Mechanical life

Times
Times
O-0.3s-CO-180s-CO
50
2000

Mechanical characteristics of VD4 and VS1-12 vacuum circuit breaker
When the circuit breaker is used to control the motor of 3~10kV, must apply metal-oxide arrester if the starting current is smaller than 600A, details should be determined by both users and manufacturer through negotiation. When the circuit breaker is used to disconnect the capacitor bank, rated current of the capacitor bank should not exceed 80% of rated current of circuit breaker.

Είδος Unit Δεδομένα
Clearance between open contacts
Overtravel
Phase-to-phase central distance
Closing contact bounce time
Three-phase opening asynchrony
mm
mm
mm
ms
ms
11±1
4±0.5
210±0.5,250±0.5,275±0.5
≤2
≤2
Breaking time at operating voltage of Μέγ
Rating
Ελάχ
ms
ms
≤50
≤50
≤60
Closing time
Average closing speed
Average closing speed
Conductive circuit resistance
Contact pressure
ms
m/s
m/s
μΩ
N
≤100
0.9-1.2
0.6-0.8
≤40
3200±100

Technical parameters of operating mechanism

Είδος Unit Value
Rated operating voltage Closing coil V DC220,110
Closing coil V DC220,110
Coil power Closing coil W 245
Closing coil W 245
Power of energy-storage motor
Rated voltage of energy-storage motor
Energy-storage time
W
V
S
50
DC220,110
≤10

Main technical parameters of ZN-12 (VHI) vacuum circuit breaker

Είδος Unit Παράμετρος
Ονομαστική τάση
Ονομαστική συχνότητα
Rated current
Rated short-circuit breaking current
Rated short-circuit making current
Rated peak withstand current
Rated short-time withstand current
Rated short-circuit duration
Rated breaking current of single capacitor bank
Rated breaking current of back-to-back capacitor bank
Power frequency withstand voltage
Lightning impulse withstand voltage
Rated short-circuit current breaking times
Mechanical life
KV
Hz
ΕΝΑ
KA
KA
KA
KA
s
ΕΝΑ
ΕΝΑ
KV
KV
Times
Times
12
50
1250
31.5
80
80
31.5
4
630
400
42
75
50
1000
Rated operating sequence O-0.3S-CO-180s-CO
Opening time
Closing time
Control voltage
Power of closing coil
Power of opening coil
ms
ms
V
VA
VA

Normal service conditions

1.Ambient air temperature: -15ºC~+40ºC;

2.Relative humidity: daily mean not over 95%, monthly mean not over 90%;

3.Υψόμετρο: not exceed 4000m;

4.Seismic intensity: not beyond Ms8;

5The installation site should be free of fire, explosive danger, serious pollution, chemical corrosion or severe vibration.

Special requirements beyond above conditions should be determined by both users and manufacturer through negotiation.

Αποστολή & Συσκευασία

Shipping Details: Standard Export carton
Shipping Details: 7-30 day after receing the deposit

Rmu MID-Set Type Metal-Clad and Metal-Enclosed Switchgear

Company Information

HONLE Electric Co.Ltd. is the manufacturer which specializes in developing, producing and marketing
industrial electrical products. It has three factories, the first one produces power supply, the second
one produces power transformer, and the third one produces complete set of equipment. As a member of
China Power Supply Society, since HONLE is founded, the company has been insisting on the theoretic
guideline ofscience &technology is the first productive forceand holding up brand strategy as the guideline, relying on forwarding power supply technology, perfecting craft and unwearied pursuing to quality. We can
show top quality and set up positive image of enterprisein domestic and foreign market.

Rmu MID-Set Type Metal-Clad and Metal-Enclosed Switchgear
Rmu MID-Set Type Metal-Clad and Metal-Enclosed Switchgear

Our Service

1.Your inquiry related to our product & price will be replied within 48 ώρες

2.Well-trained & experienced staff are to answer all your inquiries in English

3.Working time: 8:00am ~17:30pm, Monday to Saturday. (UTC+8)

4.Customized solution & perfect after-sale service

5. Payment: we can accept T/T, L/C, Western Union.

6. For large order, engineer can be sent to your country for on-site mainternace instructions.

FAQ

Rmu MID-Set Type Metal-Clad and Metal-Enclosed Switchgear