(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer

Αριθμός Μοντέλου.
C2

IP Rating
IP65

Πιστοποίηση
ISO

Προσαρμοσμένο
Προσαρμοσμένο

Output
Analog Sensor

Χρήση
Hall Sensor

Theory
Hall Sensor

Supply Voltage
+-12, +-15

Power Consumption
<25

Offset Voltage
@IP=0 +-20

Galvanic Isolation
@ 50Hz, AC, 1min 2.5

Isolation Resistance
@ DC 500V 1000

Πακέτο μεταφοράς
Export and Air-Worthy Standard Carton

Προσδιορισμός
IEC 6044-1

Εμπορικό σήμα
HEYI

Προέλευση
Liushi, Yueqing, Zhejiang Province, Κίνα

Κωδικός HS
8542390000

Παραγωγική ικανότητα
100000ΤΕΜ/Έτος

Περιγραφή

C2 series dismountable hall effect current sensor is an open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.

Electrical data (Ta=25ºC±5ºC,RL=2KΩ,CL=10000PF)
Type C2-100A C2-200A C2-300A C2-400A C2-500A Unit
Rated current(Ipn) ±100 ±200 ±300 ±400 ±500 ΕΝΑ
Measure range(Ip) 0-±200 0-±400 0-±600 0-±800 0-±1000 ΕΝΑ
Rated output @Ip=±Ipn ±4±1% V
Supply voltage ±12,±15 V
Power Consumption <25 mA
Offset voltage @Ip=0 ±20 mV
Magnetic offset @Ip=±Ipn-0 ±20 mV
Offset drift @ -40~+85ºC ≤±1 mV/ºC
Output drift @ -40~+85ºC ≤±1 mV/ºC
Linearity @Ip=0-±Ipn ≤1 %FS
Response time @50A/μS, 10%-90% ≤5 μs
Galvanic isolation @ 50HZ,AC,1min 2.5 KV
Isolation resistance @ DC 500V 1000

Εφαρμογές

·Variable speed drives
·Welding machine
·Battery supplied applications
·Uninterruptible Power Supplies (Σκαμπανεβάσματα)
·Electrochemical

Mechanical dimension(for reference only)


Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation: 1:+15V 2:-15V 3:V0UT 4:0V

Directions for use

1. When the current will be measured goes through a sensor, the voltage will be measured at the output end.(Note: The false wiring may result in the damage of the sensor)
2. Custom design in the different rated input current and the output voltage are available.

Standards

·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000

General date
Value Unit
Θερμοκρασία λειτουργίας(TA) -40 to +85 ºC
Θερμοκρασία αποθήκευσης(TS) -40 to +125 ºC
Mass(περίπου) (M) 70 σολ

Characteristics chart

Pulse current signal response characteristic:
(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer

Effects of impulse noise:

(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer