Beschreibung

Spezifikation
| Modell | NS-5 | NS-10 | |||||
| Nennspannung | AC125V | AC250V | DC30V | AC125V | AC250V | DC30V | |
| Resistive load | 5EIN(10EIN) | 5EIN(10EIN) | 4EIN | 5EIN(10EIN) | 5EIN(10EIN) | 4EIN | |
| Light load | NC:1.5A NO:0.7EIN | NC:1A NO:0.5EIN | 2EIN | NC:1.5A NO:0.7EIN | NC:1A NO:0.5EIN | 2EIN | |
| Inductive load | 3EIN | 2EIN | NC:3A NO:3EIN | 3EIN | 2EIN | NC:3A NO:3EIN | |
| Motor load | NC:2.5A NO:1.3EIN | NC:1.5A NO:0.8EIN | 3EIN | NC:2.5A NO:1.3EIN | NC:1.5A NO:0.8EIN | 3EIN | |
| Contact appearance | Rivet | ||||||
| Contact material | AgSnO2 | ||||||
| Min applicable load | DC5V 160mA | ||||||
| Operating speed | 0.1mm~1m/s | ||||||
| Permissible operating frequency | Mechanical:200 operations/min Electrical:30 operations/min | ||||||
| Contact resistance | 30mΩ max. (Initial value) | ||||||
| Isolationswiderstand | 100mΩ min.(at DC500V) | ||||||
| Spannungsfestigkeit | 1000v, 50/60Hz 1min between terminals of the same polarity | ||||||
| 1500v, 50/60Hz 1min between each terminal and no-current-carrying metal parts | |||||||
| 1500v, 50/60Hz 1min between current-carrying metal parts and ground | |||||||
| Protection grade / PTI | IEC IP40 / 175 | ||||||
| Protection grade of electric shock | Klasse | ||||||
| Operating ambient | Temperatur: -25°C ~ 125°C(with no icing or condensation) Luftfeuchtigkeit: 60% RH max. |
||||||
| Endurance | Mechanical: 1,000,000 operations min. Elektrisch: 50,000 operations min. |
||||||
Contact Form


Wiring Diagram

| Operation chatacteristics | NS-10 | NS-5 | NS-5-F | |
| Operating force | OF Max. | 1.47N | 1.47N | 0.59N |
| Releasing force | RF Min. | 0.25N | 0.25N | 0.04N |
| Pre-travel | PT Max. | 0.6mm | 0.5mm | 0.5mm |
| Over-travel | OT Min. | 0.4mm | 0.5mm | 0.5mm |
| Movement differential | MD Max. | 0.12mm | 0.1mm | 0.1mm |
| Operating position | OP | 8.4±0.5mm | ||