DC 4-20mA Input Current Signal Isolator with 4-20mA Output

Modell Nr.
BM-DI

IP -Bewertung
IP44

Zertifizierung
DAS

Angepasst
Angepasst

Input Current
DC 4-20mA or 0-20mA

Frequenz
45-65Hz

Output Signal
DC 4-20mA,0-20mA,0-5V or 0-10V

Energieversorgung
AC 85-265V,DC100-350V or DC48V

Zertifikat
DAS

Garantie
2 Jahre

Transportpaket
Paper Carton

Spezifikation
0.5kgs

Warenzeichen
ACREL

Herkunft
Jiangsu, China

HS-Code
9030339000

Produktionskapazität
1000PCS/Week

Beschreibung

Produktbeschreibung

dc 4-20ma input current Signal Isolator with 4-20mA output

BM series isolate and convert electrical parameters (z.B. current, voltage, frequency,
power and power factor) in the power grid into DC analog signal or digital signal.The product complies with IEC-688.

Functions and Parameters

functions and parameters of dc current signal isolator

*CE approval

*Accuracy:0.5

*Input signal:DC4-20ma,dc 0-20ma
*Linear Output signal:DC 4-20ma,dc 0-20ma,dc0-5v or dc0-10v
*Auxiliary power:AC 80-270V DC100V-350V or DC24V
*Installation:din rail 35mm or screw mounted

Data sheet

BM-DI DC current transducer / DC signal isolator data sheet
Input
Input current
DC 4-20ma,dc 0-20ma
Frequency range
45Hz-65Hz
Ausgabe
Output signal
4-20mA,0-20mA,0-5V or 0-10V
Output load resistance
RL≤600Ω(output current signal)
RL≥1KΩ(output voltage signal)
Parameter
Stromversorgung
AC/DC80-270V DC100-350V or DC24V/DC48V
Rated power consumption
current,voltage:≤3VA,Leistung:≤4VA
Accuracy
0.50%
Ansprechzeit
≤400mS
Temperature drift
≤200ppm/ºC
Isolation intensity
(Among input//output//power supply)
2.0kV/1min, 50Hz
Isolationswiderstand
≥100MΩ(between input-ouput-power)
Arbeitstemperatur
-20ºC~+55ºC
Installation
Din rail 35mm


Related power transducer types

Name Modell Funktion
Current signal isolator BM-DI/IS transmit dc current signal to 4-20mA output
BM-DIS/I passive isolator,standard 4-20mA input,the signal is isolated through 2000V and proportional output is 4-20mA
BM-AI/IS transmit 0-5A AC current to 4-20mA output
BM-DI/I dc current signal is 3-port isolated through 2000V,and output is 4-20mA and ground return can be removed
BM-DI/V dc current signal is 3-port isolated through 2000V,and output signal is 0-5V DC and ground return can be removed
Voltage signal isolator BM-DV/IS Transmit dc voltage signal to 4-20mA output
BM-AV/IS transmit ac 0-450v voltage to 4-20mA output
BM-DV/V dc voltage signal is 3-port isolated through 2000V,and output signal is DC 0-5V and ground return can be removed
BM-DV/I dc voltage signal is 3-port isolated through 2000V,and output signal is 4-20mA and ground return can be removed
1 in 2 out signal isolator BM-DI/II dc current signal is isolated to 2 output 4-20mA independent signal output
BM-DV/II dc voltage signal is isolated to 2 output 4-20mA independent signal output
BM-DI/VI dc current signal is isolated to 2 independent analog signal output,1 channel is 4-20mA and another channel is 0-5V
BM-DV/VI dc voltage signal is isolated to 2 independent analog signal output,1 channel is 4-20mA and another channel is 0-5V
Temperature signal isolator BM-TR/IS PT100 input,signal is isolated through 2000V voltage and proportional output is 4-20mA
Resistance signal isolator BM-R/IS Supply 4-20mA output and 2000V voltage isolation for standard 2-line resistance signal
potentiometer signal isolator BM-VR/IS Supply 4-20mA output and 2000V voltage isolation for 350Ω-10KΩ potentiometer,and there is surge protection circuit in the module
Current signal alarm isolator BM-DI/J dc current input,dual channel alarm output and dc current off-limt alarm
Voltage signal alarm isolator BM-DV/J dc voltage input,dual channel alarm output and dc voltage off-limt alarm
Temperature signal alarm isolator BM-TR/J pt100 input,dual channel output and temperature off-limit alarm
Temperature signal isolator BM-TR/I PT100 input signal is isolated through 2000v voltage and proportional output is 4-20mA
BM-TC/I thermocouple input,proportional output is 4-20mA,it has cold-junction compensation(CJC) and there is surge protection circuit in the module
BM-TC/V thermocouple input,proportional output is 0-5V,it has cold-junction compensation(CJC) and there is surge protection circuit in the module


Payment and Delivery

1. Zahlung:100% TT in advance or 30% TT as deposit and balance before shipment, Western Union ,credit card and paypal are also acceptable.

2. Lieferzeit:in 15 working days after payment received for small order .
3. Delivery ways:Auf dem Seeweg,air,train or international courier like Fedex,TNT,DHL and UPS.

About ACREL

Professional manufacturer with over 18 Jahre experience in energy meters,current transducers,signal isolator,etc.
DC 4-20mA Input Current Signal Isolator with 4-20mA Output