(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer

Modell Nr.
C2

IP -Bewertung
IP65

Zertifizierung
ISO

Angepasst
Angepasst

Ausgabe
Analog Sensor

Verwendung
Hall Sensor

Theorie
Hall Sensor

Versorgungsspannung
+-12, +-15

Power Consumption
<25

Offset Voltage
@IP=0 +-20

Galvanic Isolation
@ 50Hz, Wechselstrom, 1min 2.5

Isolation Resistance
@ DC 500V 1000

Transportpaket
Export and Air-Worthy Standard Carton

Spezifikation
IEC 6044-1

Warenzeichen
HEYI

Herkunft
Liushi, Yueqing, Zhejiang Province, China

HS-Code
8542390000

Produktionskapazität
100000Stück/Jahr

Beschreibung

C2 series dismountable hall effect current sensor is an open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.

Electrical data (Ta=25ºC±5°C,RL=2KΩ,CL=10000PF)
Typ C2-100A C2-200A C2-300A C2-400A C2-500A Einheit
Nennstrom(Ipn) ±100 ±200 ±300 ±400 ±500 EIN
Measure range(Ip) 0-±200 0-±400 0-±600 0-±800 0-±1000 EIN
Rated output @Ip=±Ipn ±4±1% v
Versorgungsspannung ±12,±15 v
Power Consumption <25 mA
Offset voltage @Ip=0 ±20 mV
Magnetic offset @Ip=±Ipn-0 ±20 mV
Offset drift @ -40~+85ºC ≤±1 mV/ºC
Output drift @ -40~+85ºC ≤±1 mV/ºC
Linearity @Ip=0-±Ipn ≤1 %FS
Ansprechzeit @50A/μS, 10%-90% ≤5 μs
Galvanic isolation @ 50HZ,Wechselstrom,1min 2.5 KV
Isolation resistance @ DC 500V 1000

Anwendungen

·Variable speed drives
·Welding machine
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
·Electrochemical

Mechanical dimension(for reference only)


Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation: 1:+15v 2:-15v 3:V0UT 4:0v

Directions for use

1. When the current will be measured goes through a sensor, the voltage will be measured at the output end.(Note: The false wiring may result in the damage of the sensor)
2. Custom design in the different rated input current and the output voltage are available.

Standards

·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000

General date
Value Einheit
Betriebstemperatur(TA) -40 Zu +85 °C
Lagertemperatur(TS) -40 Zu +125 °C
Mass(approx) (M) 70 g

Characteristics chart

Pulse current signal response characteristic:
(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer

Effects of impulse noise:

(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer