(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer

Model nr.
C2

IP Rating
IP65

Certificering
ISO

Tilpasset
Tilpasset

Produktion
Analog Sensor

Brug
Hall Sensor

Theory
Hall Sensor

Supply Voltage
+-12, +-15

Power Consumption
<25

Offset Voltage
@IP=0 +-20

Galvanic Isolation
@ 50Hz, AC, 1min 2.5

Isolation Resistance
@ DC 500V 1000

Transportpakke
Export and Air-Worthy Standard Carton

Specifikation
IEC 6044-1

Varemærke
HEYI

Oprindelse
Liushi, Yueqing, Zhejiang-provinsen, Kina

HS kode
8542390000

Produktionskapacitet
100000STK/År

Beskrivelse

C2 series dismountable hall effect current sensor is an open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.

Electrical data (Ta=25ºC±5ºC,RL=2KΩ,CL=10000PF)
Type C2-100A C2-200A C2-300A C2-400A C2-500A Unit
Rated current(Ipn) ±100 ±200 ±300 ±400 ±500 EN
Measure range(Ip) 0-±200 0-±400 0-±600 0-±800 0-±1000 EN
Rated output @Ip=±Ipn ±4±1% V
Supply voltage ±12,±15 V
Power Consumption <25 mA
Offset voltage @Ip=0 ±20 mV
Magnetic offset @Ip=±Ipn-0 ±20 mV
Offset drift @ -40~+85ºC ≤±1 mV/ºC
Output drift @ -40~+85ºC ≤±1 mV/ºC
Linearity @Ip=0-±Ipn ≤1 %FS
Responstid @50A/μS, 10%-90% ≤5 μs
Galvanic isolation @ 50HZ,AC,1min 2.5 KV
Isolation resistance @ DC 500V 1000

Ansøgninger

·Variable speed drives
·Welding machine
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
·Electrochemical

Mechanical dimension(for reference only)


Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation: 1:+15V 2:-15V 3:V0UT 4:0V

Directions for use

1. When the current will be measured goes through a sensor, the voltage will be measured at the output end.(Note: The false wiring may result in the damage of the sensor)
2. Custom design in the different rated input current and the output voltage are available.

Standards

·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000

General date
Value Unit
Operating temperature(TA) -40 to +85 ºC
Storage temperature(TS) -40 to +125 ºC
Mass(approx) (M) 70 g

Characteristics chart

Pulse current signal response characteristic:
(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer

Effects of impulse noise:

(Clamp on) C2-100A 200A 300A 400A 500A Open Loop Hall Effect Current Sensor 21mm Hole Diameter Split Core Current Transducer