40A DC Immune Current Transformer 0.2 Class for Energy Meter

Model nr.
ZMDCT05

Insulating Medium
Insulating Paper

Installation
Active Type

Magnetic Circuit Structure
Combined Type

Voltage Transformation Principle
Capacitive Type

Turns Ratio
2500:1

Transportpakke
Cartons

Specifikation
ISO9001, ISO14001, ROHS, CE, SGS

Varemærke
zeming

Oprindelse
Kina

HS kode
8504311000

Produktionskapacitet
1200000STK/År

Beskrivelse

40A DC immune Current Transformer ZMDCT05
1.Specifikation
Characteristics Values
Operating frequency 50 Hz ~ 400 Hz
Operating temperature -40ºC ~ 85ºC
Relative humidity ≤95%
Rated primary current Ip 40EN
Maximum primary operating current Imax 48EN
Testing current for DC component 40A/Root 2 <3%
Rated second current 16mA
Transformation ratio 1:2500
User supplied burden resistor 10Ω
Accurate operating current range 1.66%Ip~Imax
INPUT: 2.5A R:100Ω, f: 60HZ OUTPUT: 99.5~100mV
Power frequency withstand voltage 3Kv/1min
Insulation resistance >500MΩ/500Vdc
Interturn insulation 40A/1min
Accuracy class 0.2class

Accuracy class With the percentage(%)of Ip
1.66 5 20 100 120
Ratio Error (±%) 0.2 0.2 0.2 0.2 0.2
Phase Displacement(±·) 12 12 12 12 12

2.Structure and Size

Current direction:

Primary current is from K to L, secondary current is from Black line to White line.

3.Dimension

40A DC Immune Current Transformer 0.2 Class for Energy Meter

4.Material List

Ingen. Materiale Spec. model UL code Manufacturer
1 Inner core Nano-crystalline core / ZEMING
2 Outer core Amorphous core / ZEMING
3 Core shell PBT E238981 QINGDAO QINKE ENGINEERING PLASTICS
4 Winding 2500T E258243 ELEKTRISOLA HANGZHOU CO LTD
5 Outside shell Black E238981 QINGDAO QINKE ENGINEERING PLASTICS
6 Epoxy resin TXH-9201-10 epoxy resin insulating compound E196959 TIANJIN XINQIAO INSULATING MATERIAL CO
7 Leading wire UL1007, 26AWG,
Black&Hvid
E315651 ZHEJIANG CHENGBAO WIRE & CABLE
9 Stik Molex 5264-2P / Shenzhen Pinshang Electronic
10 Tape Flame retardant,
Environmental protection
E165111 JINGJIANG YAHUA PRESSURE SENSITIVE
GLUE CO LTD

40A DC Immune Current Transformer 0.2 Class for Energy Meter
40A DC Immune Current Transformer 0.2 Class for Energy Meter
40A DC Immune Current Transformer 0.2 Class for Energy Meter
40A DC Immune Current Transformer 0.2 Class for Energy Meter
40A DC Immune Current Transformer 0.2 Class for Energy Meter
40A DC Immune Current Transformer 0.2 Class for Energy Meter
40A DC Immune Current Transformer 0.2 Class for Energy Meter
40A DC Immune Current Transformer 0.2 Class for Energy Meter
40A DC Immune Current Transformer 0.2 Class for Energy Meter
40A DC Immune Current Transformer 0.2 Class for Energy Meter