33kv Automatic Recloser with Control Box

نموذج رقم.
AR-3S-33

تخصيص
140كجم

علامة تجارية
New Concept

أصل
Yangzhou

رمز النظام المنسق
8535210000

السعة الإنتاجية
300أجهزة الكمبيوتر / الشهر

وصف

33kV 800A Automatic Recloser with Control Box

The AR-3S-33 series circuit reclosers are recently-developed pole-mounted intelligent vacuum circuit reclosers of a new generation, which absorb the advanced domestic and foreign technologies adopted by our company. It is intelligent, energy-saving, environmentally-friendly and maintenance-free.

This product integrates such functions as control, protection, measurement, fault positioning, online monitoring and synchronous closing. With full functions and high digitalized and intelligent degree, it is a best choice for power distribution equipment network automation and intellectualization process.

This product conforms to IEC60044-1, IEC60060, IEC60068-2, IEC60099-4, IEC60255-27, IEC60270, IEC60280.1, IEC60529, IEC60694, IEC60815-1, IEC60870-5-101, IEC61000-4, IEC61243-5, IEC62271, المعايير, إلخ.

Major Technical Parameters are shown below:

الفولطية kV 33
التصنيف الحالي أ 800/1250
Rated frequency هرتز 50
1min power frequency withstand voltage (to earth/open contacts) kV 70
Rated lightning impulse withstand voltage (to earth/open contacts) kV 170
Rated short circuit break current kA 12.5/16
Rated short circuit making current (peak) kA 25/31.5
Thermal stable current() kA 25/31.5
Rated short circuit current break time Time 20
Closing time ms ≤100
Opening time ms ≤70
Average open speed m/s 1.3~1.8
Average close speed m/s 1.0~1.7
Mechanical time Time 10000
Rated operation sequence of circuit breaker O-t1-CO-t2-CO-t2-CO-lockout*
Current transformer ratio خياري
Accuracy degree خياري
Shell protection degree IP64
وزن كلغ 140

* – time can be adjustable. t1: 0.1-0.3ق, t2: 1-3ق

Our advantages:
1. Most parts are manufactured ourselves, like: frame, cabinet, permanent magnet mechanism, insulation part, control panel, إلخ. That means the process quality control is effectively controlled.
2. Adopt fast algorithm with patent technology (patent number: ZL200720037710.7) so as to obtain fast breaking capacity of circuit breaker. As a result, it can isolate fault circuit rapidly. It takes less than 25ms from inspecting fault to cut fault circuit by separate circuit breaker. It can avoid the problem of override trip effectively.
3. Adopt single phase earthing protection system with patent technology (patent number: ZL201020178325.6). It can realize on-line judgment to single phase earthing fault of low current earthing system without adding device. Releases warning or tripping action according to setting value

Our service:
1. Pre-sale technical support, training;
2. On-site factory inspection is accepted;
3. Open atitude for cooperation;
4. Punctual goods delivery;
5. After-sale technical support and service.


33kv Automatic Recloser with Control Box