304 Strainless Steel Differential Pressure Transmitter

Model NO.
QP-86

Certification
CE

Customized
Customized

Static Pressure
0~3.5 MPa

Accuracy
≤0.25%Fs

Output Signal
4~20mA

Material
Stainless Steel

Product Name
304 Strainless Steel Differential Pressure

Transport Package
Carton Box

Specification
CE, Ex

Trademark
QYE

Origin
Shaan Xi, Hanzhong

HS Code
9026201090

Production Capacity
1000/Month

Description

Liquid Gas Differential Pressure Transmitter/ Static Differential Pressure Sensor
Model:
QP-86 Differential Pressure Transmitter for Liquid and Gas/ Static pressure Sensor
Differential pressure range:10~2500 KPa
Static Pressure range:0~3.5 MPa
 
Feature:
Measuring differential pressure
Small in size, light in weight,easy to install
Various output scheme:0/4~20mA, 0/1~5V, or0/1~10V
Have the characteristics of high precision, good stability, long working life and high reliability.
Suitable for measuring gases and liquids.

Technical Specifications

Measuring media Gases or liquids which are compatible to 316L stainless steel
Differential pressure range KPa 10~2500
Static pressure range MPa 0~3.5
Pressure type Differential(D)
Signal output transmitter, mA (2 wires) 4~20mA
transmitter, Vdc (3 wires) 0~5V, 1~5V, 0~10V, 0~20mA
Accuracy %FS ±0.25(Standard), ±0.5(Max)
Long stability ±0.5%FS/year (≤200Kpa) ,  ±0.2%FS/year (≤2000Kpa)
Power supply Vdc 12~36(Standard 24Vdc)
Compensated temp. ºC -10~+60
Operating temp. ºC -20~+80
Temperature coefficient of ZERO %FS/10ºC ±0.3%FS(≤100Kpa) ,  ±0.2%FS(>100Kpa)
Temperature coefficient of SPAN %FS/10ºC ±0.3%FS(≤100Kpa) ,  ±0.2%FS(>100Kpa)
Insulation resistance >500 @ 100Vdc
Electrical connection DIN43650,Aviation connector,Directly lead (Selectable)
Material Housing Material Stainless steel(1Cr18Ni9Ti)
Material of diaphragm 316L Stainless steel
Pressure connection M20x1.5, M14x1.5, G1/4,ZG1/4 Special requirements may be based on customer demand
Environmental protection IP 65
safe overload %FS 150
Ultimate overload %FS 200

Electrical connection:

Ordering code: model- differential-static pressure-signal output-accuracy-pressure connection-electrical connection-defend grade-the other requests.
             Example: QP-86-0/500KPa-0/2.5MPa-4/20mA-0.25%FS-M20x1.5-DIN43650-IP65-***